Banner DF-G1-NR-2M Quick Start Manual

Df-g1 expert dual display fiber optic light receiver

Advertisement

DF-G1 Expert
Light Receiver

Quick Start Guide

Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies
For complete technical information about this product, including dimensions, accessories, and specifications, see
www.bannerengineering.com
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to
serious injury or death. This device does not include the self-checking redundant circuitry necessary
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an
energized or de-energized sensor output condition.
Overview
Figure 1. DF-G1 Model Features
Models
Model
Outputs
DF-G1-NR-2M
Single NPN
DF-G1-PR-2M
Single PNP
DF-G1-NR-Q5
Single NPN
DF-G1-PR-Q5
Single PNP
DF-G1-NR-Q7
Single NPN
DF-G1-PR-Q7
Single PNP
1 Connector options:
A model with a QD connector requires a mating cordset.
For 9 m cable, change the suffix 2M to 9M in the 2 m model number (example, DF-G1-NR-9M).
For 150 mm (6 in) PVC pigtail, M8 Pico QD connector, 4-pin change the suffix 2M to Q3 in the 2 m model number (example, DF-G1-NR-Q3).
Original Document
172436 Rev. C
Dual Display Fiber Optic
and search 176768.
17 March 2014
1
Output LED
2
LO/DO Switch
3
RUN/PRG/ADJ Mode Switch
4
Lever Action Fiber Clamp
5
Red Signal Level
6
Green Threshold
7
+/SET/- Rocker Button
1
Connector
2 m (6.5 ft) cable, 4-wire
150 mm (6 in) PVC pigtail, M12 Euro QD connector,
4-pin
Integral M8 Pico QD connector, 4-pin
172436

Advertisement

Table of Contents
loading

Summary of Contents for Banner DF-G1-NR-2M

  • Page 1: Quick Start Guide

    Red Signal Level Green Threshold +/SET/- Rocker Button Figure 1. DF-G1 Model Features Models Model Outputs Connector DF-G1-NR-2M Single NPN 2 m (6.5 ft) cable, 4-wire DF-G1-PR-2M Single PNP DF-G1-NR-Q5 Single NPN 150 mm (6 in) PVC pigtail, M12 Euro QD connector,...
  • Page 2: Installation Instructions

    ™ DF-G1 Expert Dual Display Fiber Optic Light Receiver Installation Instructions Mounting Instructions Mount on a DIN Rail 1. Hook the DIN rail clip on the bottom of the DF-G1 over the edge of the DIN rail (1). 2. Push the DF-G1 up on the DIN rail (1). 3.
  • Page 3: Wiring Diagrams

    ™ DF-G1 Expert Dual Display Fiber Optic Light Receiver Wiring Diagrams NPN Models PNP Models 1 = Brown 2 = White 3 = Blue 4 = Black Euro NOTE: Open lead wires must be connected to a terminal block. Pico For cable options, see http:// www.bannerengineering.com...
  • Page 4: Remote Input

    ™ DF-G1 Expert Dual Display Fiber Optic Light Receiver Remote Input For more information about how to perform TEACH/SET methods and to program the sensor remotely, see www.bannerengineering.com and search 176768. Run Mode Run mode allows the sensor to operate normally and prevents unintentional programming changes. The +/SET/- rocker button is disabled during RUN mode, except when using Window SET, see Window SET on page 9.
  • Page 5: Program Mode

    ™ DF-G1 Expert Dual Display Fiber Optic Light Receiver Program Mode Program (PRG) mode allows the following settings to be programmed in the DF-G1: Factory Default Settings: Setting Factory Default Threshold 5000 TEACH Two-Point TEACH Selection Response 50 ms Speed Offset Percent OFF Delay 0 (Disabled)
  • Page 6: Adjust Mode

    ™ DF-G1 Expert Dual Display Fiber Optic Light Receiver Adjust Mode Sliding the RUN/PRG/ADJ mode switch to the ADJ position allows the user to perform Expert TEACH/SET methods and Manual Adjustment of the threshold(s). Two-Point TEACH • Establishes a single switching threshold •...
  • Page 7: Dynamic Teach

    ™ DF-G1 Expert Dual Display Fiber Optic Light Receiver Method Action Result SET Button a. Present the first condition. Display: Flashes "2Pt tch" then holds on "1234 2nd" b. Click the SET rocker button Remote Input a. Present the first condition. b.
  • Page 8 ™ DF-G1 Expert Dual Display Fiber Optic Light Receiver Darkest Taught Lightest Taught Condition Condition Sensor positions threshold midway between taught conditions Output OFF Output ON Darkest Position Most Light (no signal) adjusted by (saturated Manual Adjust signal) Figure 3. Dynamic TEACH (Light Operate shown) The output ON and OFF conditions can be reversed using the LO/DO switch (see LO/DO Switch in Top Panel Interface page 3).
  • Page 9: Window Set

    ™ DF-G1 Expert Dual Display Fiber Optic Light Receiver 4. Exit Dynamic TEACH. Method Action Result SET Button Click the SET rocker button TEACH Accepted Displays alternate "PASS" with % Minimum Difference 7 , Sensor returns Remote Input Single-pulse remote input to Adjust mode TEACH Not Accepted Displays alternate "FAIL"...
  • Page 10 ™ DF-G1 Expert Dual Display Fiber Optic Light Receiver Sensing window center adjusted by Manual Adjust Sensor positions window thresholds a programmable % offset from the presented condition Output OFF Output ON Output OFF Darkest Condition Most Light (no signal) Presented (saturated signal)
  • Page 11 ™ DF-G1 Expert Dual Display Fiber Optic Light Receiver Method Action Result • Present sensing condition • Click the SET rocker button SET Button Threshold Condition Accepted Displays read "wInd SEt" then • Present sensing condition alternate "PASS" with % Offset 10 ; •...
  • Page 12 ™ DF-G1 Expert Dual Display Fiber Optic Light Receiver NOTE: For Window SET and Light SET, the maximum offset threshold percent is 90%. Threshold position adjusted by Manual Adjust Sensor positions threshold a programmable % offset below the presented condition Output OFF Output ON Condition...
  • Page 13 ™ DF-G1 Expert Dual Display Fiber Optic Light Receiver Method Action Result • Present sensing condition • Click the SET rocker button SET Button Threshold Condition Accepted Displays read "Lt SEt" then alternate • Present sensing condition "PASS" with % Offset 13 ; Sensor •...
  • Page 14 ™ DF-G1 Expert Dual Display Fiber Optic Light Receiver Threshold position adjusted by Manual Adjust Sensor positions threshold a programmable % offset above the presented condition Output OFF Output ON Darkest Condition Most Light (no signal) Presented (saturated signal) Figure 7. Dark SET (Light Operate shown) Dark SET and Manual Adjust Moves switching threshold value up or down to make adjustments •...
  • Page 15: Calibration Set

    ™ DF-G1 Expert Dual Display Fiber Optic Light Receiver Method Action Result • Present sensing condition • Click the SET rocker button SET Button Threshold Condition Accepted Displays read "dr SEt" then alternate • Present sensing condition "PASS" with % Offset 16 ; Sensor •...
  • Page 16: Troubleshooting

    ™ DF-G1 Expert Dual Display Fiber Optic Light Receiver ◦ GREEN display shows the switching threshold value ◦ 2 seconds after adjustment, the GREEN display will flash 3 times to confirm • Slide Mode switch to RUN to complete operation Follow these steps to perform a Calibration SET: Note: TEACH Selection must be programmed to CAL SEt (see Program Mode...
  • Page 17: Specifications

    Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period.
  • Page 18 PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR...

Table of Contents