6. Specifications

Cardinal Health™ ALLY TO GO™
Dimensions ............................................................................................................. 19.3 x 11.1 x 7.1cm (7.6 x 4.4 x 2.8 in.)
Weight .......................................................................................................................................................... 0.4kg (0.9 lb.)
Pressure Settings .............................................................................................................. -50, -75, -100, -125, -150mmHg
IEC Classification
With respect to electric shock, fire, and mechanical hazards, conforms to IEC60601-1.
• Medical Equipment
• Equipment not suitable for use in presence of flammable anesthetic mixture with air, oxygen or nitrous oxide.
• Continuous Operation
• Type B Applied Part
• Class II Internally Powered Equipment
• IPXO
Battery
Duration (Fully Charged) .............................................................................................................................. Up to 24 hours
Electrical
External Power Supply Input ....................................................................................... 100-240VAC, 50/60Hz, 0.5Amp Max
External Power Supply Output ......................................................................................................................5VDC, 1.0Amp
Environmental and Storage Conditions
Temperature Range ................................................................................................................ 10°F (-12°C) to 110°F (43°C)
Relative Humidity Range ........................................................................................................... 60 +/-25% (35% to 85%)
Atmospheric Pressure Range..................................................................................................................... 50kPa to 110kPa
Operating Conditions
Temperature Range ......................................................................................................................40°F (4°C) to 90°F (32°C)
Relative Humidity Range ........................................................................................................... 60 +/-25% (35% to 85%)
Atmospheric Pressure Range..................................................................................................................... 80kPa to 110kPa
Therapy Timer ......................................................................................................................................................... 10 days
CAUTION: Federal law restricts this device to sale by, or on the order of, a physician.