Electrical And Auxiliary Hookup; Terminal Boards; Down Terminal Board (High Voltage); Upper Terminal Board (Low Voltage) - EdilKamin PELLKAMIN 12 Installation, Use And Maintenance Manual

Pellet fireplace
Hide thumbs Also See for PELLKAMIN 12:
Table of Contents

Advertisement

ELECTRICAL AND AUXILIARY HOOKUP

The appliance is equipped with an electrical power
cord for connection to a 230V 50 Hz socket, preferably
with a trip switch.
Variations in voltage of more than 10% can compromise
its operation.
The electrical system must be compliant; check
the operation of the earth in particular. Edilkamin is
not responsible for malfunctions resulting from an
improperly grounded system. The power line must be
of adequate section for the power of the appliance.
The power cable must not come into contact with the
flue or other hot parts of the product.

upper terminal board (low voltage)

1
2
3
free
clean contact
(AUX)

down terminal board (high voltage)

1
2
3
connection V3
14
upper terminal board (low voltage)
INSTALLATION
4
5
6
reset button
already wired
4
5
6
connection V2

TERMINAL BOARDS

The right side of the appliance (seen from the front)
has a bracket with two terminal boards:
the upper terminal board (low voltage) has a pre-
wired cable for the reset button, while the rest is for
use by Edilkamin technicians only
the lower terminal board (high voltage) is for the
electrical power and fan connections;
these connections may be made by a
qualified electrician only.
all work must be done with electrical
power switched off
7
8
9
for Edilkamin technicians only
7
8
9
lower terminal board (high voltage)
10
11
12
10
11
12
Pre-wired electrical power
connection

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

807970807980

Table of Contents