Two Stud Mounting / 16" On Center Mounting
5.2.1
Install the HATCH X-RAY using the 16-inch on center mounting configuration method by following procedure
below.
Locate the 2 wood studs (2"x4" inch) to mount the base unit plate and mark template holes and drill 5/32" holes
to depth of 3½ " as shown in Figure 9 .
Install power and control wiring, following all local codes for electrical work.
Remove the bearing block from the base unit plate by removing 4 screws (M8x25-Counter sunk) using 5 mm Allen
key as shown in Figure 10 .
Install the bearing block to the base unit plate aligning to the other 4 holes using 4 screws (M8x25-Counter sunk)
using 5 mm Allen key as shown in Figure 11 .
Take the base unit plate and route the input wires and communication cables (if remote console is used) through
the hole provided on the base unit plate as shown in Figure 12 .
Install the base unit plate on two 1½" x 3½" studs aligning to the 4 drilled holes using 4 lag bolts (M10x80) with
M10 plain washers at the 4 corner holes as shown in Figure 12 (Do not tighten fully).
Check and confirm the level of the base unit by placing the round spirit level on the bearing block and then
tightening the bolts using 17 mm box spanner as shown in Figure 13 .
Continue with the procedure, section "5.3 Procedure for Input wiring:"
5.2.2
Single Stud Mount Installation
Locate the wood stud (4"x4") to mount the base unit plate and mark template holes as shown in Figure 14 (Ensure
that the template is level on the wall using spirit level). Drill 5/32" pilot holes to the depth of 3½".
Install power and control wiring, following all local codes for electrical work.
On the base unit plate, disconnect the RJ-25(6P6C) cable from the J4 connector on the power board and disconnect
the line and neutral wires from J5 connector on the power board using screw driver as shown in Figure 15.
Remove the base unit cover clamp by removing 2 screws (M3x6-Hex socket head cap) using 2.5mm Allen key as
shown in Figure 16 .