Indicator Setup - Cardinal 225-DS Installation Manual

Dual scale input card
Table of Contents

Advertisement

For additional information on setup and calibration, refer to the 225 WEIGHT
INDICATOR Installation and Technical Manual, 8200-M538-O1.
With the indicator ON, press the SHIFT key and then press the Navigation ENTER key (red
square key in center of the Navigation arrows). The display will change to show the
SETUP/REVIEW MENU.
1.ENTER CALIBRATION AND SETUP
2.VIEW AUDIT TRAIL COUNTERS
3.CALIBRATE SCALE 1
Enter Selection: 1
SETUP MENU #1
With the SETUP/REVIEW MENU displayed, press the 1 key and then the ENTER key. The
display will change to show SETUP MENU #1.
1. USA=XXX
2. NSC=XXX
3. LFT=XXX
4. OIML=XXX
5. TIME=XX
Enter Selection:
8. NO OF SCALES=X (NUMBER OF SCALES)
With SETUP MENU #1 displayed, the current setting for the NO OF SCALES= parameter
will be shown. Note that X is the current value.
Press the 8 key, the ENTER key and then using the numeric keys, enter the number of
scales and then press the ENTER key to save the new setting and return to SETUP
MENU #1. Allowable values are: 1, 2 or 3. Note that the 225 will check for the 225-DS
card. If the card is not found, it will display an error message and default back to 1 scale.
11

INDICATOR SETUP

SETUP/REVIEW MENU
9.DEL CUSTOM TICKET
10.PRINT SETUP
^
EXIT
SETUP MENU #1
6. CLR TARE=XXX
7. CLEAR ID=XXX
8. NO OF SCALES=X
9. TOTALIZE=XXX
10. MODE OF OP=0
0
`
NEXT
8200-M535-O1 Rev B  225-DS
NORM
^
EXIT