General Specifications - Fluke 902 Calibration Information Manual

Hvac clamp meter
Hide thumbs Also See for 902:
Table of Contents

Advertisement

902
Calibration Information

General Specifications

Operating Temperature
Storage Temperature
Operating Humidity
Operating Altitude
Storage Altitude
IP Rating
Vibration Requirements
EMI, RFI, EMC
Temperature
Coefficients
Size (H X W X L)
Weight
Design Standards and
Compliance
Agency Approvals
Measurement Category
Power Requirements
4
-10 °C to +50 °C
-40 °C to +60 °C
Non condensing (< 10 °C)
90 % RH (10 °C to 30 °C)
75 % RH (30 °C to 40 °C)
45 % RH (40 °C to 50 °C)
(Without Condensation)
2500 meters above mean sea level
12,000 meters above mean sea level
IP 30 per IEC 60529
MIL-PRF-28800F Class 2 random vibration
EMI: instrument unspecified for use in EMC field ≥ 0.5 V / Meter
EMC: Meets all applicable
requirements in EN61326-1
0.1 x (specified accuracy)/ °C
(<18 °C or >28 °C)
9.1 x 3.8 x 1.7 inches
(240 x 80 x 40 mm)
1.1 lb
(310 g)
EN/IEC 61010-1, EN/IEC 61010-2-032 and relevant U.S. and Canadian Standards
P ) ; s
N10140
600 V, CAT III
CAT III equipment is designed to protect against transients in equipment in fixed-equipment
installations, such as distribution panels, feeders and short branch circuits, and lighting
systems in large buildings.
Two AA Batteries, NEDA 15 A, IEC LR6

Advertisement

Table of Contents
loading

Table of Contents