Download Print this page
Fluke 902 Specifications
Fluke 902 Specifications

Fluke 902 Specifications

Fluke 902 true-rms hvac clamp meter
Hide thumbs Also See for 902:

Advertisement

Quick Links

Fluke 902
True-rms HVAC Clamp Meter
Heating, ventilation, air conditioning (HVAC)
technicians require a service tool that can
consistently keep up with their demands.
The Fluke 902 expands the existing line of
quality Fluke clamp meters by delivering the
features necessary to diagnose and repair
HVAC systems. Combined with True RMS
technology and a CAT III 600 V rating, the
Fluke 902 helps technicians do their jobs
safely and accurately.
Use the Fluke 902 to:
Capture flue gas temperatures
Conduct flame rod testing
Measure start and run motor capacitors
Measure performance of variable frequency drives
Features include:
Capacitance
DC current to 200 uA
Contact temperature (K-type thermocouple)
True-rms
Min/Max
Hold

Specifications

Feature
Voltage dc
Voltage ac
(true-rms)
Current ac
(true-rms)
Current dc
Resistance
Continuity
Temperature*
(Type-K
thermocouple)
Capacitance
N10140
Warranty
*Error does not include Type-K thermocouple errors

Technical Data

Range
0 to 600.0 V
0 to 600.0 V
1 % ± 5 counts (50/60 Hz)
0 to 600.0 A
2.0 % ± 5 counts (50/60 Hz)
0 to 200.0 µA
0 to 9999 W
<= 30 W
-10 °C to 400 °C
(-14 °F to 752 °F)
(± 1.0 % + 1.5 °F) typical
-40 °C to -10 °C
(-40 °F to -14 °F)
(± 5.0 % + 3.3 °F) typical
1 µF to 1000 µF
Three-years
Accuracy
1 % ± 5 counts
1.0 % ± 5 counts
1.5 % ± 5 counts
± 1.0 % + 0.8 °C
± 5.0 % + 1.5 °C
1.9 % ± 2 counts

Advertisement

loading
Need help?

Need help?

Do you have a question about the 902 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fluke 902

  • Page 1: Technical Data

    Heating, ventilation, air conditioning (HVAC) technicians require a service tool that can consistently keep up with their demands. The Fluke 902 expands the existing line of quality Fluke clamp meters by delivering the features necessary to diagnose and repair HVAC systems. Combined with True RMS...
  • Page 2 • • Also used on Fluke 320 and TP1 has flat blades for wall 330 Series Clamp Meters sockets • Includes 1 pair: AC220, TP1, TL224 • CAT III 1000 V, CAT IV 600 V, 10 A Fluke. Keeping your world up and running. ™ 80PK-8 Pipe Clamp Probe 80AK Thermocouple Adapter Fluke Corporation • PO Box 9090, Everett, WA USA 98206 (for use with 80AK) Adapts Type-K thermocouple • Clamps securely to pipe from mini-connector to dual banana Fluke Europe B.V.