1. Introduction, Features and Specifications: 1.1 Introduction: sKey2 adopts the shape of anti-metal shield patent technology, realize to control one door, and can be connected with external card reader to realize the special functions such as anti-passback through wiegand wire. It can directly drive electric lock, alarm, doorbell, and external exit button and magnetic door switch.
④ stick decoration piece on the anti-dropping screw position. 2.3 Wiring Diagram sKey2 Reader mode sKey2 Standalone Acess Control mode Access control special power supply Red Black...
4. User Operation 4.1 Use Card Open Door Read valid user card once, the lock opened. 4.2 Use Card and Password Open Door Read valid user card once, then enter 4-6 digits user’s password, press “#”, the lock opened. 4.3 Use Card or Password Open Door Read user card once, the lock opened.
7. Reset to Factory Default In the state of power off, press “*” and hold, the indicator light turn on orange when power on for 1 second, press “*” within 1 second, release it until hearing two shot beep voice, then hear a long beep voice, enter the normal operation state.
9.1 Basic Operation: Basic Operation Orange Function Remark Flash 6-8 digits new password , # , repeat Modify administrator password 6-8 digits new password , # Read card 1-2000(ID) read card 8 or 10 digits card number Adding 1 card ①...
Page 7
4-6 digits key +facility code virtual card number output Single Key a 4bit output Single Key a 8bit output ⑤ Turn off Alarm Turn on Alarm for 1-3 minutes User Options Setting ⑥ Indicator Light Normally OFF Indicator Light Normally ON ⑦...
10.1 Reader Mode As a card reader, the device has the following functions: Enter Administrator Operation Red Flash Function Remark Enter administrator operation mode 6-8digits administrator password # Reader Settings Orange Orange Function Flash Flash 6-8digits new passwords #,repeat Modify Administrator Password 6-8 digits new passwords # 0-15 Facility code...
10.2 Standalone Access Control Mode Under this mode: The electric lock can be opened by reading user card or inputting user password on the device or external card reader. Read anti-stress card or input anti-stress password on the device or external card reader to open the electric lock, the external alarm will sound at the same time.