Sebury B6-EH Plus User Manual

Sebury B6-EH Plus User Manual

B6 plus series. standalone access controller
Table of Contents

Advertisement

B6 Plus Series Standalone Access Controller User Manual V1.0
B6 Plus
USER MANUAL
V1.0
http://www.sebury.com.cn
Sebury Technology Co., Ltd
第 1 页

Advertisement

Table of Contents
loading

Summary of Contents for Sebury B6-EH Plus

  • Page 1 B6 Plus Series Standalone Access Controller User Manual V1.0 B6 Plus USER MANUAL V1.0 http://www.sebury.com.cn Sebury Technology Co., Ltd 第 1 页...
  • Page 2: Table Of Contents

    4.1.16 Set Alarm-time ................................19 4.1.17 Set Anti-dismantle alarm function .......................... 19 4.1.18 Set alarm or doorbell output function........................20 4.1.19 Set Anti-crack function ..............................20 4.1.20 Set LED indicator light mode............................. 20 http://www.sebury.com.cn Sebury Technology Co., Ltd 第 2 页...
  • Page 3 5.3 Double-doors mode management menu summary table ..................32 5.4 Interlock mode management menu summary table ....................33 5.5 Demo mode management menu summary table ....................... 33 6 Precautions in use .................................... 34 7 Common troubleshooting ................................35 http://www.sebury.com.cn Sebury Technology Co., Ltd 第 3 页...
  • Page 4: Overview

     1.3 Functional unit Indicator light Indicator light Logo Infrared window Antenna Antenna Backlit key Card read area Metal case Metal case Card B6K-EH Plus,B6K-IC Plus, B6-EH Plus,B6-IC Plus B6K2-EH Plus,B6K2-IC Plus http://www.sebury.com.cn Sebury Technology Co., Ltd 第 4 页...
  • Page 5: Technical Parameters

    It includes an outlet hole with a diameter greater than 8mm and four plastic screw holes with a diameter of 6mm. Then insert four matching plastic expansion screws, fix the bottom case on the wall with four matching self-tapping screws. http://www.sebury.com.cn Sebury Technology Co., Ltd 第 5 页...
  • Page 6: Wiring

    Exit button input of zone 2 White & Black Normal open port of Relay 2 Green & Black COM2 Common port of Relay 2 Red & Black Normal close port of Relay 2 http://www.sebury.com.cn Sebury Technology Co., Ltd 第 6 页...
  • Page 7 B6 Plus Series Standalone Access Controller User Manual V1.0 http://www.sebury.com.cn Sebury Technology Co., Ltd 第 7 页...
  • Page 8 B6 Plus Series Standalone Access Controller User Manual V1.0 http://www.sebury.com.cn Sebury Technology Co., Ltd 第 8 页...
  • Page 9 B6 Plus Series Standalone Access Controller User Manual V1.0 http://www.sebury.com.cn Sebury Technology Co., Ltd 第 9 页...
  • Page 10 B6 Plus Series Standalone Access Controller User Manual V1.0 http://www.sebury.com.cn Sebury Technology Co., Ltd 第 10 页...
  • Page 11 B6 Plus Series Standalone Access Controller User Manual V1.0 http://www.sebury.com.cn Sebury Technology Co., Ltd 第 11 页...
  • Page 12 B6 Plus Series Standalone Access Controller User Manual V1.0 http://www.sebury.com.cn Sebury Technology Co., Ltd 第 12 页...
  • Page 13: Debugging

    Enter the first zone admin main menu Red slow flash Enter the second zone admin main menu Blue slow flash Enter the first zone setting status Orange Enter the second zone setting status Purple http://www.sebury.com.cn Sebury Technology Co., Ltd 第 13 页...
  • Page 14: Enter Management Menu Operation Mode

    Note: The user ID range is from 1 to 20,000 and must not be added before. User PIN is a 4~6 digits number and this number must not be 1234. Controller can add more users continuously, after the last user PIN please press the * key to exit the add User PIN status. http://www.sebury.com.cn Sebury Technology Co., Ltd 第 14 页...
  • Page 15: Exit Management Menu Operation Mode

    2 Set-card operation instead. There are only below menu numbers are effective in the zone 2 management menu: 00, 01, 02, 10-12, 21, 22, 30-36. 4.1.1 Change Admin Password 00,(New Admin Password)#,(Repeat Admin Password)# Note: New Admin Password must be 6 digits http://www.sebury.com.cn Sebury Technology Co., Ltd 第 15 页...
  • Page 16: Set Or Delete Super-Open-Password

    The valid menus for Single-door and interlock mode are: 00-04,09,10-12,20-22,30-36,40-45,50-57. The zone 1 valid menus for Double-doors mode are: 00-04,09,10-12,20-22,30-36,40-45,50-57. The zone 2 valid menus for Double-doors mode are: 00,01,02,10-12,21,22,30-36. http://www.sebury.com.cn Sebury Technology Co., Ltd 第 16 页...
  • Page 17: Limits Types Of Reading Card

    Specify ID number and input 8-digit card number to add user: 11, (ID) # 8# (8-digit format card number) #, (ID) # 8# (8-digit format card number) #, … Specify ID number and input 10-digit format card number to add user: http://www.sebury.com.cn Sebury Technology Co., Ltd 第 17 页...
  • Page 18: Delete User

    4.1.11 Set Multi-card to open door 31, 1#, default value, read 1 card to open door. 31, (2-10)#, read 2~10 cards in turn to open door(The open door method must set to: open door by card). http://www.sebury.com.cn Sebury Technology Co., Ltd 第 18 页...
  • Page 19: Set Lock Working Mode

    40, 0#, default value, if set Alarm-time to 0 means no alarm. 40, (0-99) #, Alarm-time is set from 1 to 99 minutes. 4.1.17 Set Anti-dismantle alarm function 41, 0#, default value, disable Anti-dismantle alarm function. 41, 1#, enable Anti-dismantle alarm function. http://www.sebury.com.cn Sebury Technology Co., Ltd 第 19 页...
  • Page 20: Set Alarm Or Doorbell Output Function

    Each time you press the “2” key, it increase the level of brightness. Press and hold on the “2” key, the brightness will continuously increase. When it reaches to the maximum brightness the controller will beep twice. http://www.sebury.com.cn Sebury Technology Co., Ltd 第 20 页...
  • Page 21: Set Key Backlit Mode

    Note: When the # key is used as doorbell key, if the # key is the first key, then it is doorbell function, If the # key is after the digital key, then it is confirm function. http://www.sebury.com.cn Sebury Technology Co., Ltd 第 21 页...
  • Page 22: Set Doorbell Key Mode

    168,16118, the actual output is 16816118, the RS232-TTL-ASCII-10 format is 0011026166, the actual output is 11026166. 4.1.28.3 Set wiegand output format for reading card 62, (26-66)#, default value is 26, the Wiegand output format for reading card can be set from 26-66. http://www.sebury.com.cn Sebury Technology Co., Ltd 第 22 页...
  • Page 23: Admin Card Or Pin Operation

    0 0001 0010 0011 0100 0101 0110 0. 4.2 Admin card or PIN operation Admin card is divided into zone 1 and zone 2, admin card in different zone operate in different zone, the following http://www.sebury.com.cn Sebury Technology Co., Ltd 第 23 页...
  • Page 24: Set-Card Operation

    Super-open-password can open the door. 4.2.6 Anti-duress-card operation Read Anti-duress-card. Note: Anti-duress-card have the same authority with Super-open-password. The only difference is after reading Anti-duress-card, the door will open while outputting alarm signal. http://www.sebury.com.cn Sebury Technology Co., Ltd 第 24 页...
  • Page 25: Authorization-Card Operation

    Read user card, read user card, ... Open door by User card or PIN: Read user card or (User PIN)# Open door by User card and PIN: Read user card, (User PIN)# http://www.sebury.com.cn Sebury Technology Co., Ltd 第 25 页...
  • Page 26: Other Operations

    The three control wires, LED_R, LED_G and BEEP, their functions are as follows: LED_G: Green LED control wire, LED turns to green when low level. LED_R: Red LED control wire, LED turns to red when low level. http://www.sebury.com.cn Sebury Technology Co., Ltd 第 26 页...
  • Page 27: Operation Characteristics In Single-Door Mode

    Menu Parameter or operation step Function Default value (New admin password) #, (Repeat new Change admin password 888888 admin password) 0# ,read card, read card, … Set 1-3 Set-cards Delete 3 Set-cards http://www.sebury.com.cn Sebury Technology Co., Ltd 第 27 页...
  • Page 28 Disable the buzzer Enable the buzzer 1,1,…,# Decrease the keypad tone 2,2,…,# Increase the keypad tone The # key can’t be used as doorbell key The # key can be used as doorbell key http://www.sebury.com.cn Sebury Technology Co., Ltd 第 28 页...
  • Page 29: Single-Door Mode Management Menu Summary Table

    4#, read card, read card, … Set 1-3 Anti-duress-cards. 5#, read card, read card, … Set 1-3 Authorization-cards. 6#, read card, read card, … Set 1-3 Normal-open-cards. 0000, # Delete 21 admin cards Delete 3 Set-cards. http://www.sebury.com.cn Sebury Technology Co., Ltd 第 29 页...
  • Page 30 10#(10-digit format number)#, 10#(10-digit Specified ID number and input 10-digit format number)#, … format card number to delete user. (ID)#, (ID)#, … Input ID number to delete user. http://www.sebury.com.cn Sebury Technology Co., Ltd 第 30 页...
  • Page 31 Key backlit is always on After delay 2-99 seconds, Key backlit turn to (2-99)# micro light 1,1,…,# Decrease the brightness of the backlit 2,2,…,# Increase the brightness of the backlit Disable the buzzer http://www.sebury.com.cn Sebury Technology Co., Ltd 第 31 页...
  • Page 32: Double-Doors Mode Management Menu Summary Table

    Input 8-digit format card number to add 8#(8-digit format card number)#,8#(8-digit format card number)#, … users. 10#(10-digit format card number)#,10#(10-digit Input 10-digit format card number to add users. format card number)#, … http://www.sebury.com.cn Sebury Technology Co., Ltd 第 32 页...
  • Page 33: Interlock Mode Management Menu Summary Table

    5.5 Demo mode management menu summary table Way to enter menu : * (Hold down for more than 2 seconds), (Admin password) # Menu Parameter or operation step Function Default value Reader mode Single-door mode http://www.sebury.com.cn Sebury Technology Co., Ltd 第 33 页...
  • Page 34: Precautions In Use

    The factory default mode is the single-door mode. If you need other mode functions, you must enter the appropriate  mode to operate properly. In different modes, the management menu is also different. http://www.sebury.com.cn Sebury Technology Co., Ltd 第 34 页...
  • Page 35: Common Troubleshooting

    Reading card distance is too close. Choose the qualified lock or parallel 2. Part of the electrical lock interference is connect a 470uF/25V electrolytic capacitor too large. at the two ends of the lock http://www.sebury.com.cn Sebury Technology Co., Ltd 第 35 页...

Table of Contents