LED Indications for Diagnostic Modes
Overview
When any of the special diagnostic switch settings are recognized and the unit is performing the special diagnostic function, the LEDs will flash in a
unique and special sequence to indicate both, the diagnostic feature being executed as well as the successful completion status.
The general sequence will be to flash on all the green LEDs 3 times. After the 3rd flash the unit will turn on the LED(s) that indicate the code for the
appropriate diagnostic function being performed.
Special Diagnostic Modes
Reset Factory Defaults
888
Complete Restore to Factory Settings
(i.e. initialized to "out of box" condition)
IP Address:
Subnet Mask:
Gateway Address:
LEDS status
Reset Communication Settings
707
Restore Upper Static IP to:
IP Address:
Subnet Mask:
Gateway Address:
LEDS status
Phone: 248-435-0700 Toll Free: 800-635-0289 Fax: 248-435-8120 www.ametekfactoryautomation.com
192.168.1.1
255.255.255.0
192.168.1.254
192.168.1.1
255.255.255.0
192.168.1.254
Parameter Save & Restore
606
Backup All Parameters to USER I/O Module
(Note: Also Saves IP Address Modes and Settings)
IP Address:
Subnet Mask:
Gateway Address:
LEDS status
616
Restore All Parameters from USER I/O Module
(Note: Also Restores IP Address Modes and Settings)
IP Address:
Subnet Mask:
Gateway Address:
LEDS status
Saved
Saved
Saved
Restored
Restored
Restored
®