Chapter 6
Web Server
To help aid in configuring the units IP address and user settings, there
is an internal web server in the Network LDT. These web pages can be
used to monitor and configure the Network LDT. The intent of the web
pages are to provide nearly the same functionality that exists through
the CIP network interface.
6.1Main Web Page
The Main web page is loaded when the module's IP address is specified
by the users' web browser. The Main page provides an introduction to
the module, its capabilities and the modules identification information.
Navigation through the site is done with the tabbed menu or the menu
links on the home page. The Configuration menu has multiple pages
and a tabbed submenu will be displayed on those pages.
Displayed on the Home
page:
• General product and
company introduction
• Menu to all other web
pages
• Position & Status
• Configuration
• Diagnostics
• Module Part Number
• Module Serial Number
6.2 Position Status Page
The Position Status web page displays the current position and status
data of the module.
Displayed on the
Position Status page:
• Position Value
• Velocity Value
• Direction of Travel
• Status and Alarm Flag
Status
6.3 Position Sensor Configuration Page
The Position Sensor Configuration web page provides an interface to
view and set the position sensor parameters.
Phone: 248-435-0700 Toll Free: 800-635-0289 Fax: 248-435-8120 www.ametekfactoryautomation.com
Displayed and settable via the Position Sensor Configuration page:
• Direction Counting
Toggle
• Position Format
• Position Measuring
Increment
• Position Filter Type
• Position Low Limit
• Position High Limit
• Velocity Format
• Velocity Filter Type
• Minimum Velocity
Setpoint
• Maximum Velocity
Setpoint
• Fault Output Type
• Sync Mode
The page will also provide
the ability to set the Preset
Value to calibrate the
position to the current
location.
The Load button will load the pending values into the working
parameters in memory; no save to non-volatile will be done.
The Save button will load the pending values into the working
parameters in memory and write the resulting configuration to the User
configuration storage.
The Factory Save button will load the pending values into the working
parameters in memory and write the resulting configuration to the
Factory configuration storage. – Note: This button appears on the
screen but is non functional unless the appropriate password has been
entered under the Diagnostics Tab. The Factory Save values should
never be altered unless instructed to do so by the factory.
The RapidRecall™ Reset button will take the current values stored in
the RapidRecall Module and save them to the LDTs RAM and User
Configuration Store. This function acts the same as if the DIP switches
on the RapidRecall™ Module were set to "616"
The RapidRecall™ Save button will take the current values stored in the
LDTs RAM and write them to the RapidRecall™ Module. This function
acts the same as if the DIP switches on the RapidRecall Module were
set to "606"
6.4 Ethernet Configuration Web Page
The Ethernet Configuration web page provides the ability to view and
set the Ethernet configuration parameters.
Displayed and settable via the Ethernet Configuration web page:
• IP Address
• Subnet Mask
• Gateway Address
• DHCP Enable
The Save button will load the
pending values into the working
parameters in memory and write
the resulting configuration to the
User configuration storage.
®