Table 5– Max Suggested Firing rate for a Given Combustion Chamber Size
1
Air Cone Size
1A
2A
3A
4A
Cast iron air cone
P/N:13003
Cast iron air cone
P/N:101366-001
*-
Chamber size not recommended with given firing rate
1. Listed air cone size is a general recommendation for the given firing rates, this can vary
depending on the different sized baffles and air handling parts that are used within the burner.
Firing
Square
Rate
Chamber
(gal/hr)
0.75
*
1.00
*
1.25
*
1.35
*
1.50
*
1.65
*
1.75
*
2.00
*
2.50
*
3.00
15 1/2" x 15 1/2"
3.00
15 1/2" x 15 1/2"
3.50
17 3/4" x 17 3/4"
4.00
19" x 19"
4.50
20" x 20"
5.00
23 1/4" x 23 1/4"
24 x 1/2" x 24
6.00
1/2"
35
Diameter
Rectangular
Round
Chamber
Chamber
10"
8" x 9"
11"
10" x 10"
12"
11" x 11"
12"
11" x 11"
13"
11" x 12"
14"
12" x 13"
14"
12" x 13"
15"
13" x 14"
17"
14" x 16"
17 1/2"
13" x 18 1/2"
17 1/2"
13" x 18 1/2"
20"
15" x 23"
23 1/2"
16" x 22 1/2"
*
17" x 23 1/2"
*
18" x 25"
*
23" x 28 1/2"
Rect.
Nozzle
Chamber
Distance
Height
to Floor
9"
4"
10"
4 1/2"
11"
5"
11"
5"
12"
5"
13"
5"
13"
5"
13 1/2"
5 1/2"
14"
5 1/2"
14"
7"
14"
7"
15"
7 1/2"
16"
8"
17"
8 1/2"
18"
9"
20"
10"