Wayne EHASR-DC Manual page 12

Oil burners
Table of Contents

Advertisement

BURNER WILL LIGHT, BUT 12Vdc WAYNE OIL PRIMARY CONTROL GOES INTO LOCKOUT
Procedure
6.
Check cad cell sighting
for view of flame.
-
De-energize burner.
-
Unplug cad cell and
clean face with soft
cloth. Check cad cell
positioning for view
of flame. Place cad
cell back in socket.
-
Re-energize burner.
7.
Check Control & Cad
cell.
-
Remove cad cell
wires from
connectors on the oil
primary control and
leave lead wires
unconnected.
-
Energize burner
-
Place jumper across
cad cell terminals
after burner motor
turns on.
(CONT)
Status
Burner locks out.
Burner keeps running, until "call
for heat" is satisfied.
Burner doesn't run.
Burner runs.
Corrective Actions
Go to step 7
System is okay.
Replace primary control.
Control is okay, replace cad cell.
12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eh-dc

Table of Contents