Wayne 12Vdc Oil Primary Control - Wayne EHASR-DC Manual

Oil burners
Table of Contents

Advertisement

Figure 5- Wiring Diagram for 12Vdc EH-DC & EHASR-DC burner without Igniter Drop-Out
Timer (Igniter-Continuous Duty)

WAYNE 12Vdc OIL PRIMARY CONTROL

Figure 6- Wayne 101382 series 12Vdc Oil Primary Control
OIL PRIMARY CONTROL FEATURES
The 12Vdc Wayne 101382 series oil primary control is an option used on 12Vdc oil burners. The 12Vdc oil primary control
is used with a cad cell flame sensor to control the oil burner's sequence of operation. The 101382 series control is
equipped with one of three different timings and features. The 101382-001 is the standard control, the 101382-002 is
designed for quick starts when used on a pressure washer, and the 101382-003 is equipped with a post-purge feature see
sequence of operation for details on each one. All oil primary controls are potted and sealed to protect against harsh
operating environments. The oil primary control has built in over-current protection to protect the oil burner from
component failure. The oil primary control comes equipped with diagnostic LED lights to indicate system status and assist
in troubleshooting. See fault chart for a list of fault codes while troubleshooting oil primary control.
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eh-dc

Table of Contents