Advertisement

WAYNE COMBUSTION SYSTEMS
801 GLASGOWAVE.
FORT WAYNE, IN 46803
ffiffiDEt
|lfisR.Dc
0lt
ffism
&
BIJANERS
Pu blication D ate 31 24n1o3
Flevision D
Manual 22019-003
)#
ELECTRIC SHOCK HAZARD
HIGH VOLTAGES ARE PRESENT IN THIS EQUIPMENT,
FOLLOW THESE RULES TO AVOID ELECTBIC SHOCK.
A Use only a properly grounded circuit. A ground fault
interrupter is recommended.
A Do not spray water directly on burner.
A Turn off power before servicing.
A Read the owner's manual before using.
c
OVERHEATING HAZARD
SHOULD OVERHEATING
OCCUR:
A Shut off the manual oil valve to the appliance.
A Do not shut off the control switch to the oumo or blower.
NEVER ATTEMPT TO USE
GASOLINE AS A FUEL FOR
THIS BURNER, AS IT IS MORE COMBUSTIBLE
AND
COULD RESULT IN A SERIOUS EXPLOSION.
MODET MSR SPECIFIGATIOI{S
FIRING CAPACITIES MODEL MSR
FOR VOUR SAFETY
DO NOT STORE OR USE GASOLINE OR
OTHER FLAMMABLE VAPORS AND LIQ-
UIDS IN THE VICINITY OF THIS OR ANY
OTHER APPLIANCE.
O.5O TO 2.75 GALLONS PER HOUR
70,000 To 385,000 BTU/HR TNPUT
FUELS
Use No. 1 or No. 2 Heating Oil (ASTM D-396), Kerosene, Diesel & JP8 Jet Fuel.
- NEVER attempt to use gasoline as a fuel for your burner, as it is more combustible and could result in a seri-
ous explosion.
ELECTRICAL
Po wer S upp ly
..........tt 5 V I 6 O HZ / 1 P H
Motor.....,...
,..........,..3450
RPM, N.E.M.A. 48 Flange, Manual Reset Overload Protection
lgnition.......
,.,..,..,..,..10,000V
I 23MA secondary, Continuous Duty-Shielded,
Interrupted
Duty Shielded Transformer, or Solid-State lgnition System,
DTMENSTONS (STANDARDI
FUEL PUMPS
HEIGHT.....
..............11%"
Suntec or Danfoss - Single Stage Standard
wlDrH
.............
....tsvj:'
MOUNTTNG
DEP TH......
.... .. . . .. . .. . .. 6 % " "
Rigid Flange, Adjustable Flange, or Base Mount
INSTALLATION OF BURNER
INSTALLATION OF THE BURNER MUST BE DONE BY A QUALIFIED INSTALLER IN ACCORDANCE WITH REGULATIONS OF THE NATION.
AL FIRE PROTECTION STANDARD FOR OIL-BURNING EOUIPMENT, NFPA NO. 31, AND IN COMPLETE ACCORDANCE WITH ALL LOCAL
CODES AND AUTHORITIES HAVING JURISDICTION.
A QUALIFTED INSTALLER tS THE PERSON WHO IS RESPONSIBLE FOR THE INSTALLATION AND ADJUSTMENT OF THE EQUIPMENT
ANQ WHO lS LTCENSED TO TNSTALL O|L-BURNTNG EOUIPMENT tN ACCORDANCE WrTH ALL CODES AND ORDINANCES. WARRANTY
IS VOIDED IF NOT INSTALLED BY SERVICE PEHSON.
THESE INSTRUCTIONS SHOULD BE AFFIXED TO THE BUHNER
OR ADJACENT TO THE HEATING APPLIANCE.

Advertisement

Table of Contents
loading

This manual is also suitable for: