STARTING BURNER

Be sure that the starter switch on the equipment is in the "OFF" position, set the thermostat to a temperature substantially
above room temperature, and ensure the oil tank is filled, all valves are open, and controls set for operation. Adjust air
supply on burner by loosening screw on interlocking air bands, and open the air band until black smoke is eliminated on
start-up (see Figure 20).
Once black smoke is eliminated measure the air band open according to Figure 21 with a ruler and mark it
down in the notes of this manual for the next service.
Open the ignition device mounting plate and turn on the burner switch if one is present.
Next, bleed the pump by following steps 1-3 before starting the burner. See
valve on the pump.

STARTING PROCEDURE

Figure 20– Air Band Adjustment Screw Location
Figure 21– Air Band Opening
Figure 22
30
Air Band
Adjustment
Screw
for the location of the bleeder