Advertisement

Quick Links

Nio Fusion 12MP
User guide
MDNC-12130
ENABLING BRIGHT OUTCOMES

Advertisement

Table of Contents
loading

Summary of Contents for Barco Nio Fusion12MP

  • Page 1 Nio Fusion 12MP User guide MDNC-12130 ENABLING BRIGHT OUTCOMES...
  • Page 2 Barco NV Beneluxpark 21, 8500 Kortrijk, Belgium www.barco.com/en/support www.barco.com Registered office: Barco NV President Kennedypark 35, 8500 Kortrijk, Belgium www.barco.com/en/support www.barco.com...
  • Page 3: Table Of Contents

    Table of contents 1 Welcome!.......................................... 5 What's in the box ....................................6 At a glance ......................................6 Compatible Barco system components..........................9 2 Installation and setup..................................11 Single workstation setup................................12 Dual workstation setup with KVM switch ...........................13 QAWeb registration ..................................16 VESA-mount installation ................................16 VESA-mount installation in portrait mode .........................19...
  • Page 4 4.15 Ambient Light Compensation (ALC).............................32 4.16 Reading rooms ....................................32 4.17 Continuous Ambient Light Compensation (ALC)......................33 4.18 Embedded QA ....................................33 4.18.1 About Embedded QA..............................33 4.18.2 DICOM status report ..............................34 4.18.3 DICOM compliance check .............................34 4.18.4 DICOM calibration ..............................35 4.18.5 Reset DICOM calibration............................35 4.18.6 DICOM error threshold.............................35 4.19...
  • Page 5: Welcome

    Welcome! What's in the box ..........................6 At a glance.............................6 Compatible Barco system components.....................9 R5913350 /02 Nio Fusion 12MP...
  • Page 6: What's In The Box

    • Cables for Mains, Video and USB If you ordered a Barco display controller, it is also in the box together with its accessories. A dedicated user guide is available on the documentation disc. Keep your original packaging. It is designed for this display and is the ideal protection during transport and storage.
  • Page 7 Welcome! Jog dial • Press: Activate the shortcut bar, go into (sub)menus, confirm adjustments and selections • Turn left/right: Scroll through (sub)menus, change values, make selections • Press and hold for approximately 3 seconds: Cancel adjustments, exit (sub)menus • Double-press: Cycle through the SoftGlow light modes (when the KVM switch is disabled) Switch KVM inputs (when the KVM switch is enabled) Side USB-A 2.0 downstream connector...
  • Page 8 Welcome! Bottom USB-A 2.0 downstream connector 12. USB-B 2.0 upstream connector 1 (Main) 13. USB-B 2.0 upstream connector 2 (Secondary, used only with KVM switch enabled) 14. DisplayPort IN 1 (also Main for KVM switch) 15. DisplayPort IN 2 (also Secondary for KVM switch) 16.
  • Page 9: Compatible Barco System Components

    1.3 Compatible Barco system components Overview Following Barco components are compatible with your Nio Fusion 12MP display: • QAWeb Enterprise version 2.5 or later, or MediCal QAWeb version 1.13.20 or later •...
  • Page 10 Welcome! R5913350 /02 Nio Fusion 12MP...
  • Page 11: Installation And Setup

    Installation and setup Single workstation setup .......................12 Dual workstation setup with KVM switch ..................13 QAWeb registration ........................16 VESA-mount installation .......................16 VESA-mount installation in portrait mode..................19 R5913350 /02 Nio Fusion 12MP...
  • Page 12: Single Workstation Setup

    Connect the supplied mains cable to a grounded power outlet. For a list of compatible display controllers, please refer to the compatibility matrix available on my.barco.com (MyBarco > My Support > Healthcare > Compatibility Matrices > Barco Systems Compatibility Matrices)
  • Page 13: Dual Workstation Setup With Kvm Switch

    Your display will be running in a basic video mode at a default refresh rate when first time starting up. Install the MXRT driver and Intuitive Workflow Tools When using a Barco MXRT display controller, install the MXRT driver and Intuitive Workflow Tools on the connected workstation. Barco’s Intuitive Workflow Tools are designed to increase visibility of subtle details, improve focus during reading sessions, and accelerate workflow.
  • Page 14 Connect the supplied mains cable to a grounded power outlet. For a list of compatible display controllers, please refer to the compatibility matrix available on my.barco.com (MyBarco > My Support > Healthcare > Compatibility Matrices > Barco Systems Compatibility Matrices)
  • Page 15 Your display will be running in a basic video mode at a default refresh rate when first time starting up. Install the MXRT driver and Intuitive Workflow Tools When using a Barco MXRT display controller, install the MXRT driver and Intuitive Workflow Tools on both connected workstations. Barco’s Intuitive Workflow Tools are designed to increase visibility of subtle details, improve focus during reading sessions, and accelerate workflow.
  • Page 16: Qaweb Registration

    Learn more at www.barco.com/qaweb. To register your display system to your QAWeb Enterprise organization, the QAWeb Enterprise Agent must be installed and running on your workstation and it must be able to communicate with the QAWeb Enterprise cloud service.
  • Page 17 Installation and setup Overview The panel, standard attached to a stand, is compatible with the VESA 100 mm standard. Thus, it can be used with a mount that is compliant to the VESA 100 mm standard. This chapter shows you how to release the panel from the stand and how to attach it to a VESA mount.
  • Page 18 Installation and setup Image 2–7 5. Rotate the VESA mount cover to uncover the screws fixing the panel to the stand. Image 2–8 6. Unscrew the 4 fixation screws while supporting the stand. Image 2–9 7. Attach the panel firmly to the VESA mount using 4 M4 screws. Respect the following rule to select an appropriate screw length: = T + W + 6.5 mm = T + W + 10 mm...
  • Page 19: Vesa-Mount Installation In Portrait Mode

    Installation and setup Image 2–10 2.5 VESA-mount installation in portrait mode Introduction By default, your Nio Fusion 12MP display is mounted in landscape position but it can also be used in portrait position. This section explains how to install and use the display in portrait orientation. Carefully follow the instructions hereafter to ensure proper product operation and to avoid physical damage to the product.
  • Page 20 Installation and setup R5913350 /02 Nio Fusion 12MP...
  • Page 21: Daily Operation

    Daily operation Recommendations for daily operation ....................22 Shortcut bar ..........................22 Standby switching.........................23 SoftGlow light mode switching .......................23 KVM input switching ........................24 OSD menu access and use ......................24 R5913350 /02 Nio Fusion 12MP...
  • Page 22: Recommendations For Daily Operation

    LCD displays use technology based on pixels. As a normal tolerance in the manufacturing of the LCD, a limited number of these pixels may remain either dark or permanently lit, without affecting the diagnostic performance of the product. To ensure optimal product quality, Barco applies strict selection criteria for its LCD panels.
  • Page 23: Standby Switching

    To adjust the brightness of the SoftGlow lights, please refer to “SoftGlow Task light”, page 27 and “SoftGlow Wall light”, page 27. The SoftGlow lights can also be enabled and configured in the Intuitive Workflow Tools. See the Barco “Display Controller and Intuitive Workflow Tools” user guide on the included documentation CD, or at www.barco.com/support.
  • Page 24: Kvm Input Switching

    Daily operation 3.5 KVM input switching About the KVM switch The Nio Fusion 12MP can be used in a dual workstation setup with KVM switch. This allows the display to be connected to two different workstations and control both with a single keyboard and mouse connected to the display.
  • Page 25: Advanced Operation

    Advanced operation OSD menu language ........................26 OSD menu orientation........................26 OSD menu automatic close function....................26 Power lock function........................26 SoftGlow Task light ........................27 SoftGlow Wall light........................27 DPMS mode..........................28 Hibernate .............................28 Luminance target..........................29 4.10 Color presets..........................29 4.11 Color space..........................30 4.12 Viewing modes ..........................31 4.13 Display functions ..........................31 4.14 sRGB ............................32 4.15 Ambient Light Compensation (ALC) ....................32...
  • Page 26: Osd Menu Language

    Advanced operation 4.1 OSD menu language About the OSD menu language By default, the OSD menu comes up in English. However, there’s a wide range of other languages available for the OSD menu of your Nio Fusion 12MP. To change the language of the OSD menu: Bring up the OSD main menu.
  • Page 27: Softglow Task Light

    The SoftGlow lights can also be enabled more quickly via the shortcut bar. See “SoftGlow light mode switching”, page 23. The SoftGlow lights can also be enabled and configured in the Intuitive Workflow Tools. See the Barco “Display Controller and Intuitive Workflow Tools” user guide on the included documentation CD, or at www.barco.com/support.
  • Page 28: Dpms Mode

    Advanced operation The SoftGlow lights can also be enabled and configured in the Intuitive Workflow Tools. See the Barco “Display Controller and Intuitive Workflow Tools” user guide on the included documentation CD, or at www.barco.com/support. To adjust the SoftGlow Wall light brightness Bring up the OSD main menu.
  • Page 29: Luminance Target

    Advanced operation Hibernate will be automatically disabled on your display when enabling the KVM switch (see“KVM switch”, page 36). To enable/disable hibernate Bring up the OSD main menu. Navigate to the Configuration > Power Management menu. Enter the Hibernate submenu. Select Enabled/Disabled as desired and confirm.
  • Page 30: Color Temperature

    Advanced operation 4. Select one of the available color presets and confirm. 4.10.1 Color temperature About color temperature: It is possible to change the color temperature of your display. Color temperature can only be changed when the Color preset is set to User. To change the color temperature: 1.
  • Page 31: Viewing Modes

    DICOM: DICOM (Digital Imaging and Communications in Medicine) is an international standard that was developed to improve the quality and communication of digital images in radiology. In short, the DICOM display function results in more visible grayscales in the images. Barco recommends selecting the DICOM display function for most medical viewing applications.
  • Page 32: Srgb

    Advanced operation Enter the Display Function submenu. Select one of the available display functions and confirm. 4.14 sRGB About sRGB When sRGB is enabled, the display is set to an sRGB color space with the following settings: • Color preset: 6500K. See “Color presets”, page 29 for more info. •...
  • Page 33: Continuous Ambient Light Compensation (Alc)

    Various settings for both actions can be selected from the display’s OSD menu. The last results of both actions can be consulted from the OSD. Embedded QA or QAWeb? Embedded QA is not a replacement for the Barco QAWeb solution. R5913350 /02 Nio Fusion 12MP...
  • Page 34: Dicom Status Report

    Advanced operation Although Embedded QA is a reliable option to perform a simple calibration or compliance test, Barco still highly recommends QAWeb as the solution of choice for calibration and QA. QAWeb brings many benefits such as centralized asset management, the ability to schedule tasks, remote management, automated reporting, alerting and specific support of regional QA standards such as DIN 6868-57, JESRA and AAPM TG18.
  • Page 35: Dicom Calibration

    Advanced operation 4.18.4 DICOM calibration About DICOM calibration The DICOM calibration will add a correction to the current DICOM curve to approach the perfect DICOM curve as well as possible. To start DICOM calibration: Bring up the OSD main menu. Navigate to the Configuration >...
  • Page 36: Image Source Selection

    Advanced operation To enable/disable image scaling: Bring up the OSD main menu. Navigate to the Configuration > Image Source menu. Enter the Scaling submenu. Select Enabled/Disabled as desired and confirm. 4.20 Image source selection About image source selection By default, your Nio Fusion 12MP automatically detects the connected image sources and attaches them to the correct side of the screen.
  • Page 37: Grayscale Conversion Modes

    Advanced operation Enter the KVM Switch submenu. Select Enabled/Disabled as desired and confirm. When enabling the KVM switch, the Image Source Selection menu will be inaccessible. In addition, Hibernate will be disabled to guarantee correct USB port switching also when one or both workstations are in sleep mode.
  • Page 38: Edid Format

    Advanced operation To select the DisplayPort standard version Bring up the OSD main menu. Navigate to the Configuration > Image Sources > Input Settings > DisplayPort 1/2 menu. Enter the Input Interface Standard Version submenu. Select one of the available versions and confirm. To obtain full resolution and full refresh rate, DP V1.2 should be selected and two DisplayPort video input cables must be connected to the display.
  • Page 39: Display Info

    4.28 SteadyColor™ About SteadyColor Barco’s SteadyColor technology was created to achieve consistency and perceptual linearity in the display of color images. With multiple internal sensors, the display parameters are constantly monitored and adjusted to ensure that the perceptual difference between colors is proportional with their Digital Driving Level (DDL) difference.
  • Page 40 Advanced operation Enter the keycode: 9-0-0-1. Enter the Service menu. Navigate to the Maximum Luminance demo submenu and confirm. The maximum luminance demo is activated. Press the jog dial to manually cancel the maximum luminance demo, or wait for 60 seconds after which the demo is automatically cancelled.
  • Page 41: Cleaning Your Display

    Cleaning your display R5913350 /02 Nio Fusion 12MP...
  • Page 42: Cleaning Instructions

    Cleaning your display 5.1 Cleaning instructions To clean the display Apply a cleaning/disinfecting product to a soft lint-free cloth, such as a microfiber or gauze and rub the display surface thoroughly. In order to be effective, all surfaces must be cleaned for a certain amount of time (ranging from 30 seconds to 2 minutes).
  • Page 43: Repackaging Instructions

    Repackaging instructions R5913350 /02 Nio Fusion 12MP...
  • Page 44: Repackaging Instructions

    Repackaging instructions 6.1 Repackaging instructions To repack your display 1. Put the display in the lowest position and lock the stand locking mechanism. Image 6–1 2. Place the display in the bottom buffer on a stable surface. Caution: It takes 2 persons to safely execute this action. Image 6–2 3.
  • Page 45 Repackaging instructions Image 6–3 4. Position the front buffer. Image 6–4 5. Slide the accessory box(es) and all cables in the dedicated cavities. R5913350 /02 Nio Fusion 12MP...
  • Page 46 Repackaging instructions Image 6–5 6. Slide the display and the accessories in the box. Image 6–6 7. Close and seal the box. R5913350 /02 Nio Fusion 12MP...
  • Page 47 Repackaging instructions Image 6–7 R5913350 /02 Nio Fusion 12MP...
  • Page 48 Repackaging instructions R5913350 /02 Nio Fusion 12MP...
  • Page 49: Important Information

    Important information Safety information.........................50 Environmental information......................51 Regulatory compliance information ....................53 EMC notice ..........................54 Explanation of symbols .........................57 Legal disclaimer ...........................60 Open source license information....................60 Technical specifications.........................61 R5913350 /02 Nio Fusion 12MP...
  • Page 50: Safety Information

    Important information 7.1 Safety information General recommendations Read the safety and operating instructions before operating the device. Retain safety and operating instructions for future reference. Adhere to all warnings on the device and in the operating instructions manual. Follow all instructions for operation and use. Electrical Shock or Fire Hazard To prevent electric shock or fire hazard, do not remove cover.
  • Page 51: Environmental Information

    For more information about recycling of this product, please contact your local city office or your municipal waste disposal service. For details, please visit the Barco website at: http://www.barco.com/AboutBarco/weee R5913350 /02...
  • Page 52 Electronic Products ” (Also called RoHS of Chinese Mainland), the table below lists the names and contents of toxic and/or hazardous substances that Barco’s product may contain. The RoHS of Chinese Mainland is included in the MCV standard of the Ministry of Information Industry of China, in the section “Limit Requirements of toxic substances in Electronic Information Products”.
  • Page 53: Regulatory Compliance Information

    Mainland, marked with the Environmental Friendly Use Period (EFUP) logo. The number inside the EFUP logo that Barco uses (please refer to the photo) is based on the “General guidelines of environment-friendly use period of electronic information products” of Chinese Mainland.
  • Page 54: Emc Notice

    The manufacturing country of the product is indicated on the product label (“Made in …”). Importers contact information To find your local importer, contact one of Barco’s regional offices via the contact information provided on our website (www.barco.com). FCC class B This device complies with Part 15 of the FCC Rules.
  • Page 55 Important information Electromagnetic emissions The Nio Fusion 12MP is intended for use in the electromagnetic environment specified below. The customer or the user of the Nio Fusion 12MP should assure that it is used in such an environment. Electromagnetic environment – Compliance Emissions test Guidance...
  • Page 56 Important information Electromagnetic Immunity test Compliance level IEC 60601 test levels environment – guidance requires continued IEC 61000-4-11 0% residual voltage for 1 0% residual voltage for 1 operation during power period at 0° period at 0° mains interruptions, it is 70% residual voltage for 70% residual voltage for recommended that the Nio...
  • Page 57: Explanation Of Symbols

    Important information Test Immunity Maximum Distance frequency Band (MHz) test level (V/ Service Modulation power (W) (MHz) 5240 5100 – 5800 W LAN Pulse 802.11 a/n modulation 5500 217 Hz 5785 7.5 Explanation of symbols Symbols on the device On the device or power supply, you may find the following symbols (nonrestrictive list): Indicates the device meets the requirements of the applicable EC directives/ regulations.
  • Page 58 Important information Indicates the device is approved according to the PSE regulations. Indicates the device is approved according to the RCM regulations. Indicates the device is approved according to the EAC regulations. Caution: Federal law (United Stated of America) restricts this device to sale by or on the order of a licensed healthcare practitioner.
  • Page 59 Important information Warning: dangerous voltage Caution Consult the Instructions For Use. Consult the Instruction For Use on website address that is provided as eIFU indicator. eIFU indicator Indicates this device must not be thrown in the trash but must be recycled, according to the European WEEE (Waste Electrical and Electronic Equipment) directive.
  • Page 60: Legal Disclaimer

    Barco software products are the property of Barco. They are distributed under copyright by Barco NV or Barco Inc., for use only under the specific terms of a software license agreement between Barco NV or Barco Inc. and the licensee. No other use, duplication, or disclosure of a Barco software product, in any form, is authorized.
  • Page 61: Technical Specifications

    Barco whatsoever. You further acknowledge that any such additions, changes or modifications may impair the ability of Barco – at Barco’s sole discretion - to continue to provide service, warranties, software updates, fixes, maintenance, access or such similar abilities, without any recourse or claim towards Barco whatsoever.
  • Page 62 Important information Maximum luminance (panel 1200 cd/m² typical) DICOM calibrated luminance 600 cd/m² Contrast ratio (panel typical) 1500:1 Response time ((Tr + Tf)/2) 10 ms (average, with all single transitions within 1 frame period) (typical) Housing color Black / White Video input signals 2x DisplayPort 1.2 USB ports...
  • Page 63 Packaging Directive * Some of the listed certifications may still be pending. For the actual list of applicable certifications, please refer to the product page on www.barco.com or see the certification marks on the product label of your display. Supplied accessories...
  • Page 64 Important information Relation of storage and operating humidity and temperature Image 7–1 R5913350 /02 Nio Fusion 12MP...
  • Page 66 Barco NV President Kennedypark 35 8500 Kortrijk Belgium R5913350 /02 | 2021-01-26 www.barco.com...

Table of Contents