Power Source Disturbances; Power Entry; Power Cord - Qualstar RLS-8350 Product Specification

Tape library
Hide thumbs Also See for RLS-8350:
Table of Contents

Advertisement

4.1.1 Power Source Disturbances

The RLS will continue to operate uninterrupted and without damage over a one-cycle
line dropout. It is recommended that the unit be powered from an Uninterruptible
Power Source (UPS). The UPS should be rated to handle the maximum wattage.

4.1.2 Power Entry

The RLS has a line fuse and I.E.C. power receptacle mounted on the rear panel. An
internal AC line filter reduces EMI conducted emissions and protects the library and
tape drives from noise on the power lines.

4.1.3 Power Cord

The supplied detachable power cord complies with the following specifications:
• 100-125 volt
applications
• 200-240 volt
applications
RLS models equipped with two power supply modules come supplied with two power
cords to allow the library to be connected to independent power sources.
4-2
UL listed and CSA certified three-conductor 18 AWG SJT vinyl-
jacketed cord. One end is terminated with an IEC 320 C13 style
connector. The other end is terminated with a NEMA 5-15P type
plug.
Harmonized three-conductor HO5VV F3G 1.0mm vinyl-jacketed
cord. One end is terminated with an IEC 320 C13 style connector.
The other end is terminated with the European CEE7 Standard
VII type plug.
Electrical Specifications