Download Print this page

CommScope FOSC-OC-3 Installation Instruction page 2

Tray (d size) with integrated splitter

Advertisement

5
Identification
Identification can be done by means of
• colored fibers
• colored tubes
• marked tubes
• colored tapes
• flags.
Make sure not to lose ID.
FOSC-OC-3 (D size tray)
5.1
The above drawing shows the dedicated spaces (in the D tray) where the fibers are to be stored after splicing
5.2
At the end of each fiber, a flag can be attached with the
identification of the fiber. The identification is as follows:
Ix.y:
I=Incoming fiber of the splitter
x=splitter number
y=splitter port
Ox.y:
O=Outgoing fiber of the splitter
x=splitter number
y=splitter port
In case of asymmetrical splitters, the identification of the ports can be
made through the dB value that is written on the back of the flag at the
end of the fiber.
To find out more about CommScope® products, visit us on the
web at www.commscope.com
For technical assistance, customer service, or to report any
missing/damaged parts, visit us at:
http://www.commscope.com/SupportCenter
5.3
flag when available and do all necessary steps till the splice protector is
installed.
Note: Make sure not to lose fiber identification.
The fiber end can be deformed to create a higher Return Loss on the
unused fibers.
Make sure to cut the fiber end (50 mm, 2" or behind the ID flag)
before starting with the splicing steps.
5.4 Proceed with the storage of the splices and the fibers according to
the installation instruction delivered with the enclosure.
Note: Make sure the splice protector has cooled down before storing in
the splice protector modules.
© 2017 CommScope, Inc. All rights reserved.
FOSC and all trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope, Inc.
This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to
CommScope products or services.
This product is covered by one ore more U.S. patents or their foreign equivalents. For patents, see:
www.commscope.com/ProductPatent/ProductPatent.aspx.
Select the appropriate fiber to be spliced, cut the identification

Advertisement

loading

This manual is also suitable for:

Fosc-oc-3p11w00Fosc-oc-3p11g00Fosc-oc-3a21800Fosc-oc-3p11800F58883-000D39890-000 ... Show all