I can get into programming and change the feature settings, but when
I use the remote the settings change.
Are you using a binary, master dealer remote? Remember, you
can program the settings using a master dealer remote. However,
the unit follows the dealer default settings when using a binary
remote to operate the system.
Unit does not learn Dealer Master Remote.
Please refer to the Master Dealer Remotes section of this guide.
Unit goes into Programming every time the ignition is turned off.
The LED/Valet switch is probably stuck in the down position. If
the hole for the switch is too tight, the travel of the switch can be
impaired and the switch may stick in the down position. To allow
the button to travel freely, the mounting hole must not be too tight.
The alarm exits programming when I try to adjust the impact sensor.
If the LED/Valet switch is released or possibly damaged, the alarm
exits programming.
If the buttons on the remote are pressed too quickly, the alarm does
not see the Arm/Disarm command and exits programming.