    3. Keep extensions as short as possible. Use the same gauge wires for short extensions and larger gauge wires for longer extensions. 4. Before installing, discuss the placement of the LED indicator and Valet switch with the vehicle’s owner. 5. Turn off interior light(s) or remove interior light fuse to prevent battery drain. © 2002 Directed Electronics, Inc.
  • Page 4: Installation Procedures

    3. Mount the siren with the two self-tapping screws to a solid metal surface. 4. Route the siren cable through the firewall into the passenger compartment. 5. Make the wire connection as per the diagram on page 23. © 2002 Directed Electronics, Inc.
  • Page 5: Ultrasonic Sensors

    5. When satisfied with the final sensitivity setting, you may exit Installer Ultrasonic setup mode by either turning off the ignition or by pressing any remote control button. Program mode exit will be confirmed by two siren chirps (one short and one long chirp). © 2002 Directed Electronics, Inc.
  • Page 6: Pin Connector Charts

    0.75 second (-) output when activated. CAUTION: Ask the customer at the time of installation whether they require this feature. Verify the type of central locking system the vehicle has. Carefully follow the door lock/unlock diagrams on pages 13-17. © 2002 Directed Electronics, Inc.
  • Page 7 BLACK wire with GREEN tag. 3. Connect the WHITE wires to the left and right indicator light wires on the vehicle. On-Board Door Lock Relays (P1/13-P1/18) For installation instructions, see Door Lock Diagrams beginning on page 13. © 2002 Directed Electronics, Inc.
  • Page 8: 10-Pin Connector (P2)

    This last option is especially useful as if the rear windscreen was removed whilst the alarm was armed the alarm would trigger. NOTE: If you are not going to use this Input then it must be grounded or the system will report a mal- function. © 2002 Directed Electronics, Inc.
  • Page 9 1. Connect the BLACK wire with RED tag to one of the supplied fuse assemblies. 2. Connect the BLACK wires with GREEN tags to separate chassis ground locations. Connect the empty fuse assembly(s) to the positive battery post. NOTE: This wire must be a minimum of 14 gauge. © 2002 Directed Electronics, Inc.
  • Page 10: 4-Pin Pigtail Connector (P3)

    4. Connect the control unit BLACK wire marked 3 to the key side. 5. Connect the control unit BLACK wire marked 4 to the starter side. NOTE: Remove all tags from wires after connection. © 2002 Directed Electronics, Inc.
  • Page 11: Final Wiring Connections

    P2 Pin 2 BLUE/WHITE or Pin 7 BLUE Six Flashes Normally Closed Trigger Input (-) P2 Pin 4 BLACK/WHITE Seven Flashes Ultrasonic Sensor P1 Pin7/8/9 Ultrasonic sensors Eight Flashes Ignition Trigger P2 Pin 3 BLACK with ORANGE Tab © 2002 Directed Electronics, Inc.
  • Page 12: Chirp/Indicator Light Flash Interpretation

    Armed and there is a sensor input active then 4 more chirps and flashes (automatically bypassed). 2 chirps and flashes, then 5 more chirps and flashes Armed and there is a boot, bonnet, or normally closed trigger input active (automatically bypassed). © 2002 Directed Electronics, Inc.
  • Page 13: Door Lock Diagrams

    © 2002 Directed Electronics, Inc.
  • Page 14 © 2002 Directed Electronics, Inc.
  • Page 15 © 2002 Directed Electronics, Inc.
  • Page 16 © 2002 Directed Electronics, Inc.
  • Page 17 © 2002 Directed Electronics, Inc.
  • Page 18: Personal Identification Number (Pin)

    13. To enter Valet mode, now turn the ignition on and press and hold the Valet switch for three seconds until the LED illuminates constantly. The system will automatically exit Valet mode the next time the ignition is switched ON. © 2002 Directed Electronics, Inc.
  • Page 19: Programmable Features

    OFF. You will hear two chirps to confirm exit of program mode. If you wish to program additional fea- tures, leave the ignition ON and press the Valet switch again. The system will advance to the next feature. Continue pressing and releasing the Valet switch until you have reached your next chosen feature. © 2002 Directed Electronics, Inc.
  • Page 20: Programming Table For System Features

    9 times to set fourth digit of PIN code. If you require a 00 (zero, zero) in the PIN code, press buttons at the same time. Ultrasonic Sensor Test — See Explanation on Page 5. and Adjustment Mode © 2002 Directed Electronics, Inc.
  • Page 21: Programming Table For Remote Controls

    All remotes are erased from memory. NOTE: When assigning channels to different buttons from factory you must "All Channel Learn" a transmitter and then change the individual assignments with feature number 20 to 25 as required. © 2002 Directed Electronics, Inc.
  • Page 22: Final Testing Checklist

    Distribute the copies as follows: White (top) copy - Customer Blue copy - Customer’s insurance broker Pink copy - Directed Electronics UK Office Green Copy - Installing Dealer ©...
  • Page 23: Wiring Diagrams

    Wiring Diagrams NOTE: The current draw for the entire security system when in the armed state is 20mA. Power supply voltage range is 9 volts to 15 volts. © 2002 Directed Electronics, Inc.