  • Page 1 PAR Z MOVE RGBW User Instructions...
  • Page 2 ©2021 ADJ Products, LLC all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted.
  • Page 3: Table Of Contents

    CONTENTS General Information Limited Warranty (USA Only) Safety Guidelines Overview Fixture Installation DMX Set Up DMX Addressing System Menu DMX Traits: Channel Functions & Values Dimmer Mode Chart Power Linking | Cleaning Technical Specifications...
  • Page 4: General Information

    GENERAL INFORMATION INTRODUCTION Please read and understand all instructions in this manual carefully and thoroughly before attempting to operate these products. These instructions contain important safety and use information. UNPACKING The products in this kit have been thoroughly tested and have been shipped in perfect operating condition.
  • Page 5: Limited Warranty (Usa Only)

    All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return shipping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in its original package. No accessories should be shipped with the product.
  • Page 6: Safety Guidelines

    To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual. ADJ Products, LLC is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Only qualified and/or certified personnel should perform installation of this fixture and only the original rigging parts included with this fixture should be used for installation.
  • Page 7 S A F E T Y G U I D E L I N E S DO NOT TOUCH the fixture housing during operation. Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before servicing. DO NOT shake fixture;...
  • Page 8 LEDs. This issue is not specific only to ADJ lighting fixtures, it is a common issue with lighting fixtures from all manufacturers. Although there is no true way to fully prevent this issue from happening, the guidelines below can prevent any potential damage from occurring if followed.
  • Page 9: Overview

    OVERVIEW LENS SERVICE PORT IP65 Locking IP65 Locking UP Button MENU Button 5-Pin DMX In Power Connector In/Out ENTER Button DOWN Button IP65 Locking 3-Pin DMX In LCD Menu Control Display IP65 Locking IP65 Locking 3-Pin DMX Out 5-Pin DMX Out Safety Cable Attachment Point Omega Bracket...
  • Page 10: Fixture Installation

    FIXTURE INSTALLATION FLAMMABLE MATERIAL WARNING Keep fixture at least 7.9in. (0.2m) away from any flammable materials, decorations, pyrotechnics, etc. ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and/or installations. MINIMUM DISTANCE TO OBJECTS/SURFACES MUST BE 40 FEET (12 METERS) MAXIMUM TEMPERATURE OF EXTERNAL SURFACE 167°F (75°C) DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO! Fixture MUST be installed following all local, national, and country commercial electrical and construction...
  • Page 11 Screw one clamp each via a M12 screw and nut into the Omega brackets. Insert the quick-lock fasteners of the Omega brackets into the respective holes on the bottom of the Par Z Move RGBW. Tighten the quick-lock fasteners fully clockwise. Pull a safety cable through the safety cable attachment points located on the base plate and over the trussing system or a safe fixation spot.
  • Page 12 The Par Z Move RGBW is fully operational in three different mounting positions, hanging upside-down from a ceiling or trussing, sideways on trussing, or set on a flat level surface. Be sure this fixture is kept at least 12m (40ft) away from any flammable materials (decoration etc.).
  • Page 13: Dmx Set Up

    1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain. Data Cable (DMX Cable) Requirements (For DMX Operation): The PAR Z Move RGBW can be controlled via DMX-512 protocol. Your unit and your DMX controller requires a 5-pin XLR connector for data input and data output.
  • Page 14 XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior. 5-Pin XLR DMX Connectors. Some manufactures use 5-pin DMX-512 data cables for DATA transmission in place of 3-pin.
  • Page 15: Dmx Addressing

    In the case of the Par Z Move RGBW, when in 7 channel mode you should set the starting DMX address of the first unit to 1, the second unit to 8 (7 + 1), the third unit to 15 (8 + 7), and so on.
  • Page 16: System Menu

    SYSTEM MENU The fixture includes an easy to navigate system menu control panel display where all necessary settings and adjustments are made. During normal operation, pressing the MODE button once will access the fixture’s main menu. Once in the main menu, you can navigate through the different menus and the sub-menus with the UP and DOWN buttons.
  • Page 17 SYSTEM MENU Menu Submenu Options Description 001-512 DMX Address DMX Addressing 13CH / 15CH / 16CH DMX CH Mode DMX Channel Mode Selection Hold Last / Blackout / Manual No DMX Status DMX Lost Status Pan Invert: ON / OFF Reverse Pan Motion Tilt Invert: ON / OFF Reverse Tilt Motion...
  • Page 18 SYSTEM MENU Menu Submenu Options Description Power On Time - XXXXXX Hours Total Running Time (Not Resettable) P-On Time-R - XXXXXX Hours Total Running Time (Resettable) Fixture Life Time P-On Time Reset - YES/ON Reset Total Running Time (Pass Code = 50) Total LED On Running Time LED On Time - XXXXXX Hours (Not Ressetable)
  • Page 19 SYSTEM MENU ACCESS THE MAIN MENU BY PRESSING THE MENU BUTTON FOR AT LEAST 5 SECONDS. DMX SETTINGS - The submenus listed under DMX SETTINGS are as follows: DMX Address, DMX Channel Mode, and No DMX Status. • DMX ADDRESS - In this submenu you can find and set your desired DMX address. •...
  • Page 20 SYSTEM MENU INFORMATION - The submenus listed under INFORMATION are as follows: Fixture Life Time, Total LED Time, Fixture Temps, Fan Info. (RPM), DMX Values, Error Logs, and Software Version. • FIXTURE LIFE TIME • Power On Time -The TOTAL power ON running time of the unit is displayed. This time CANNOT be reset.
  • Page 21: Dmx Traits: Channel Functions & Values

    DMX TRAITS: CHANNEL FUNCTIONS & VALUES (13/15/16 DMX Channels) 13 CH 15 CH 16 CH Values Functions PAN MOVEMENT 8-BIT: 0-100% (0° - 540°) 000-255 PAN FINE 16-BIT 000-255 000-255 TILT MOVEMENT 8-BIT: 0-100% (0° - 200°) 000-255 TILT FINE 000-255 RED: 0-100% GREEN: 0-100%...
  • Page 22 13 CH 15 CH 16 CH Values Functions VARIABLE WHITE COLOR TEMPERATURE 000-020 STANDARD 021-040 STAGE 041-060 061-080 ARCHITECTURAL 081-100 THEATRE 101-120 STAGE 2 DIMMER DELAY TIME 0.1 SEC. 0.2 SEC. 0.3 SEC. 0.4 SEC. 0.5 SEC. 0.6 SEC. 0.7 SEC. 0.8 SEC.
  • Page 23 DIMMER MODE CHART...
  • Page 24 MULTIPLE POWER LINKING With this feature you can connect the fixtures to one another using the power cable input and output sockets. NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES AS THE POWER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE! CHECK SILK SCREEN FOR MAX AMPS.
  • Page 25 SPECIFICATIONS Optical: • 300W RGBW COB (Chip On Board) 4-IN-1 LED engine (Red, Green, Blue & White) • 20,000 hour LED life • Motorized Zoom: 9 ~ 37-degrees • CRI: 80 Connections: • Locking power In/Out to daisy chain power •...
  • Page 26 DIMENSIONS...
  • Page 27: Dimmer Mode Chart

    FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC RADIO FREQUENCY INTERFERENCE WARNINGS &...