Table Of Contents; Job Specification Sheet - Pentair FLECK 5810 Service Manual

Hide thumbs Also See for FLECK 5810:
Table of Contents

Advertisement

TABLE OF CONTENTS

JOB SPECIFICATION SHEET .................................................... 2
INSTALLATION ......................................................................... 3
TOUCHSCREEN CONTROL QUICK START ............................... 5
TOUCHSCREEN CONTROL FEATURES.................................... 7
MASTER SETTINGS PROGRAMMING ...................................... 10
MASTER SETTINGS REFERENCE CHART ............................... 15
MASTER RESET ....................................................................... 16
CONTROL OPERATION ............................................................. 16
ALARMS AND ERRORS ........................................................... 16
TROUBLESHOOTING ................................................................ 17
POWERHEAD ASSEMBLY......................................................... 18
5810 CONTROL VALVE ASSEMBLY .......................................... 19
5812 CONTROL VALVE ASSEMBLY .......................................... 20
5812 DRAIN LINE FLOW CONTROLS ....................................... 21
BYPASS ASSEMBLY.................................................................. 22
SAFETY BRINE VALVE .............................................................. 23
WATER CONDITIONER FLOW DIAGRAMS ............................... 24
5810 DIMENSIONAL DRAWINGS ............................................. 28
5812 DIMENSIONAL DRAWINGS ............................................. 29
WIRING DIAGRAM .................................................................... 30
INJECTOR FLOW DATA ............................................................ 31
IMPORTANT PLEASE READ:
• The information, specifications and illustrations
in this manual are based on the latest information
available at the time of release. The manufacturer
reserves the right to make changes at any time
without notice.
• This manual is intended as a guide for service
of the valve only. System installation requires
information from a number of suppliers not known
at the time of manufacture. This product should be
installed by a plumbing professional.
• This unit is designed to be installed on potable
water system only.
• This product must be installed in compliance with
all state and municipal plumbing and electrical
codes. Permits may be required at the time of
installation.
• It is established that when daytime water pressure
exceeds 80 psi (5.5 bar), the maximum pressure
rating of 125 psi (8.6 bar) can be exceeded. A
pressure regulator must be installed on this
system or warranty is voided.
• Do not install the unit where temperatures may
drop below 32°F (0°C) or above 120°F (52°C).
• Do not place the unit in direct sunlight. Black
units will absorb radiant heat increasing internal
temperatures.
• Do not strike the valve or any of the components.
• Warranty of this product extends to manufacturing
defects. Misapplication of this product may result
in failure to properly condition water, or damage to
product.
• A prefilter should be used on installations in which
free solids are present.
• In some applications local municipalities treat
water with Chloramines. High Chloramine levels
may damage valve components.
• Correct and constant voltage must be supplied to
the controller to maintain proper function.
2 • FLECK 5810 & 5812 XTR2 Service Manual

JOB SPECIFICATION SHEET

Job Number: _____________________________________________________
Model Number: ___________________________________________________
Water Hardness: ________________________________________ ppm or gpg
Capacity Per Unit: _________________________________________________
Mineral Tank Size: ______________ Diameter: _________ Height: _________
Salt Setting per Regeneration: _______________________________________
Regenerant Flow:
Downflow
Upflow Backwash
Filter Upflow Variable Refill Custom Downflow Custom Upflow
1. Meter Size:
A. 1-1/4" Turbine
2. System Type:
A. System #4: 1 Tank, 1 Meter, Immediate, or Delayed Regeneration
B. System #4: Time Clock
3. Cycle Settings:
A. Backwash: ____________________________________ Minutes
B. Brine and Slow Rinse: ___________________________ Minutes
C. Rapid Rinse: ___________________________________ Minutes
D. Brine Tank Refill: _______________________________ Minutes
E. Pause Time: ___________________________________ Minutes
F. Second Backwash: ______________________________ Minutes
4. Drain Line Flow Control:_____________________________ gpm
5. Brine Line Flow Control: ____________________________ gpm
6. Injector Size#: ________________________________________
The 5810 & 5812 - 2.5" base models are Tested and
Certified by the WQA to NSF/ANSI Std. 44 & 372 for
material safety and structural integrity & lead free
compliance and CSA B483.1.
Component
CALIFORNIA PROPOSITION 65 WARNING
This product contains chemicals known to the
WARNING:
State of California to cause cancer or birth
defects or other reproductive harm.
Downflow 2x Backwash