Pentair FLECK 5810 Service Manual page 11

Hide thumbs Also See for FLECK 5810:
Table of Contents

Advertisement

MASTER SETTINGS PROGRAMMING
continued
• language: Displays the language used on the control
(international version only): English, French, German,
Italian, or Spanish.
• units: Contains settings for the unit type (either US or
Metric) to be used in the control.
• hardness units: Contains settings for hardness units
of measure (grains per gallon, mg/L or ppm, German
degrees, French degrees, or English degrees). Hardness
units are adjustable only if metric units are selected.
NOTE: Degree hardness units are converted to ppm upon
input. Degree inputs may be rounded up or down
to the nearest ppm equivalent.
• Press the screen navigation arrows at the upper-right
and left of the screen to navigate to the Assistance Name,
Assistance Phone, and Assistance Interval screens.
See TOUCHSCREEN CONTROL QUICK START for more
information about these settings.
• Press
to save changes.
USB Connection for Field Programming
The XTR2 features a USB port that allows you to connect a PC
to the control for field programming and diagnostic parameter
download.
NOTE: Field Programmer software is required for field
programming features. See XTR2 Field Programmer
Manual for more information on using the Field
Programmer software.
Pressing
on the Format screen displays the USB screen.
Figure 20 USB Screen
When the USB screen appears, connect a USB cable to the
USB port on the control circuit board (see "WIRING DIAGRAM"
on page 27 for location of USB port). connect the other
end of the USB cable to a PC with the Field Programmer
software installed and follow the directions in the XTR2 Field
Programmer manual to complete the connection. Press
return to Master Settings.
NOTE: Do not remove USB cable from computer or control
while connected and transferring data. See the XTR2
Field Programmer manual for proper disconnection
procedure.
Valve Screen
From the main Master Settings screen (Figure 17) press the
valve button to display the Valve screen.
• system: Displays the system type. Type 4 (single system)
is currently the only available selection.
• valve: Contains settings to select the valve model
installed with the control.
• regen type: Contains settings for the type of regeneration
to use for the system. Regeneration types are described
in detail below.
Regeneration Types
The XTR2 control supports several different Regeneration
Types. The Regeneration Type defines the method of automatic
regeneration for the system. Each type is explained below.
Time Clock
Triggers a regeneration on a timed interval. The control will
initiate a regeneration cycle at the selected Regeneration Time
when the number of days since the last regeneration equals
the Day Override value. The Day Override can be set from 1 - 99
days as well as partial day intervals of 4, 8, 12, 16 and 20 hours.
Softener Immediate
Measures water usage and regenerates the system as soon
as the calculated system capacity is depleted. The control
calculates the system capacity by dividing the unit capacity by
the feed water hardness. Softener Immediate systems do not
use a reserve volume. The control will also start a regeneration
cycle at the programmed regeneration time if a number of days
equal to the Day Override pass before water usage depletes
the calculated system capacity. The Day Override parameter
default is OFF, and REGEN TIME will be grayed out unless the
day override value has been modified.
When setting the system for softener immediate
CAUTION
regeneration, setting the capacity to a value lower
than that of feed water hardness may cause the
to
system to constantly regenerate. If this occurs,
disconnect the motor from the control and correct
the capacity and feed water hardness values in
Master Settings. See "TROUBLESHOOTING" on page
17 for more information.
Softener Delayed
Measures water usage and regenerates the system at the
selected Regeneration Time after the calculated system
capacity is depleted. The control calculates the system capacity
by dividing the unit capacity by the feed water hardness and
subtracting the reserve.
FLECK 5810 & 5812 XTR2 Service Manual • 11