5. ELECTRIC ELEMENTS
For the CORFLEX PRIMAIRE direct-immersion option
It is possible to add 5 to 30 kW direct-immersion heating elements according to the following
recommended combinations:
EN
For the CORFLEX PRIMAIRE Steatite option
It is possible to add 4.8 to 24 kW steatite heating elements according to the following
recommended combinations:
Tank heating time with heating element(s) in the lower fl ange position:
These heating times are estimated for storage at 60°C and cold water at 10°C.
4,8 kW
steatite immersion steatite immersion steatite immersion steatite steatite immersion immersion
500 L
6h00
750 L
900 L
1000 L
1500 L
2000 L
2500 L
3000 L
4000 L
5000 L
** only available for the 1000 TB (low height) model.
Page 18 / 66
Immersion
Recommended
heating
combinations
element
5 kW
500 L
10 kW
750 to 1000 L
15 kW
1000 to 2000 L
25 kW
2000 to 5000 L
30 kW
2000 to 5000 L
Steatite
Recommended
heating
combinations
element
4.8 kW
500 L
9 kW
750 L to 1000 L
12 kW
1000 L TB to 1500 L
18 kW
1500 L to 2500 L
24 kW
2000 L to 5000 L
Puissances électriques résistances
5 kW
9 kW
10 kW
6h00
5h00
4h30
6h00
5h30
6h30
6h00
CORPRIMO / CORFLEX PRIMAIRE
Assembly fl ange
(point 8 in "Appendix A -
Technical Characteristics"
page 56)
DN 112
Assembly fl ange
(point 8 in "Appendix A -
Technical Characteristics"
page 73)
DN 150
DN 210
12 kW
15 kW
18 kW 24 kW
5h00 **
4h00
7h30
6h00
5h00
8h00
6h30
8h15
25 kW
30 kW
5h00
4h45
4h00
6h15
6h00
5h00
7h30
7h15
6h00
9h40
9h20
7h45
12h00
11h40
9h40
U0594059-#