Testing And Certification - STA-RITE AR204-L 3/4 HP Owner's Manual

“ar” series bronze pumps with integral trap self-priming
Table of Contents

Advertisement

IAPMO Certified
Anti-entrapment
Cover or Suction Fitting,
screw-fastened to
Main Drain Sump
Suction Outlet
(Main Drain)
Figure 1 – Recommended pump suction layout.
Suction Outlets Per Pump (Figure 1, Page 4)
Provide at least two hydraulically balanced main drains, with covers, as suction
outlets for each circulating pump suction line. The centers of the main drains
(suction outlets) on any one suction line must be at least three feet apart.
The system must be built so that it cannot operate with the pump drawing
water from only one main drain (that is, there must be at least two main drains
connected to the pump whenever it is running – See Figure 1, below).
However, if two main drains run into a single suction line, the single suction
line may be equipped with a valve which will shut off both main drains from
the pump (See Figure 1).
More than one pump can be connected to a single suction line as long as the
requirements above are met.
Water Velocity
The maximum water velocity through the suction fitting or cover for any suc-
tion outlet must be 1.5 feet per second unless the outlet complies with the lat-
est ASME/ANSI Specification for Suction Fittings For Use in Swimming Pools,
Spas, Hot Tubs, and Whirlpool Bathtub Applications. In any case, do not ex-
ceed the suction fitting's maximum designed flow rate.
If 100% of the pump's flow comes from the main drain system, the maximum
water velocity in the pump suction hydraulic system must be six feet per sec-
ond or less even if one main drain (suction outlet) is completely blocked. The
flow through the remaining main drain(s) must comply with the latest
ASME/ANSI Specification for Suction Fittings For Use in Swimming Pools,
Spas, Hot Tubs, and Whirlpool Bathtub Applications.

Testing and Certification

Suction outlet covers must have been tested by a nationally recognized testing
laboratory and found to comply with the latest ASME/ANSI Specifications for
Suction Fittings For Use in Swimming Pools, Spas, Hot Tubs, and Whirlpool
Bathtub Applications.
At Least
3 Feet
No valves between
Tee and Main Drains
Valves OK between
pump and Tee
4
IAPMO Certified
Anti-entrapment
Cover or Suction Fitting,
screw-fastened to
Main Drain Sump
Suction Outlet
(Main Drain)
Pump
2762 0197

Advertisement

Table of Contents
loading

Table of Contents