L-PAK 150/250 Standard
5.1.1

L-PAK Off (Off mode)

The unit is in Off mode, which is also the unit's start menu. The unit can also go into Off
mode if something is wrong, such as if an alarm is activated. The pump motor is off, there is
no vacuum, the FCV is closed, and the unit cannot be activated by a pilot signal.
Nederman
Hi Vacuum Unit
L-PAK
OFF
Time To Service
2000 hours
5.1.2

L-PAK Standby (Standby mode)

The unit is in Standby mode and is ready. The pump motor is off, there is no vacuum, the
FCV is closed, and the unit is waiting for a pilot signal to go into Running mode.
Hi Vacuum Unit
Standby
Waiting For
Pilot Signal
Mo 15:33
2018-01-22
5.1.3

Running (Running mode)

The unit in Running mode. The pump motor is on and the unit generates a vacuum. The
FCV is closed.
Hi Vacuum Unit
Running
Time
05:33
Min
DIRTm
00:00 s
5.1.4

Idling (Idling mode)

The unit in Idling mode. The pump motor is on, there is no vacuum, and the FCV is open.
The unit goes into Idling mode when there has been no pilot signal for the time set in DIR_
Time, see Section 6.2.4. DIR_Time.
Hi Vacuum Unit
IDLING
Time To
StandBy
05:33m
8
TimeToService: The amount of time until next scheduled service. The
default setting is 2000 hours. See Section 6.2.2. H-Meter 1.
ESC
OK
ESC
OK
DIRTm: The amount of time before the unit goes into Idling mode. The
default is 10 seconds. See also Section 6.2.4. DIR_Time.
OTTmr: If the Overtime timer has been activated, OTTmr shows the
elapsed time since the overtime timer started.
ESC
OK
Time: The number of minutes the fan engine has been running since the
last start.
Time to Standby: The amount of time until the unit goes into Standby
mode. The default setting is 12 minutes. See Section 6.2.3. SSR_Time.
ESC
OK