This product is designed to meet the requirements of relevant EC directives. To maintain this status, all installa- tion, maintenance, and repair is to be done by qualified personnel using only Nederman original spare parts and accessories. Contact the nearest authorized distributor or Nederman for advice on technical service and obtain- ing spare parts.
2.1 Download error log via USB Open the lid to the control box. Connect a USB memory stick or computer to the FilterBox USB contact, and close the lid to download the er- ror log. Wait 2 minutes and then open the lid and disconnect the computer, or remove the USB memory stick.
2.4 Warnings Table 2.2 Warnings Error Solution Detect low cleaning efficiency Check the cleaning motor (FilterBox A and eQ). Cleaning interval too intermittent Check the cleaning motor (FilterBox A and eQ). Time to change Main Filter Change the main filter. HEPA Filter clogged (Hi dp) Change the HEPA-filter.