Table 11 Optional Specifications For Explosion Protected Types (Continued)
CENELEC ATEX (KEMA) Flameproof Approval*2
❑ Applicable standard: EN50014, EN50018
❑ Certificate: KEMA 02ATEX2159
❑ II 2G EEx d IIC T6 and T5 Amb. Temp.: –40 to 75 °C (–40 to 167 °F) for T6, –40 to 80 °C (–40 to
176 °F) for T5
CENELEC ATEX (KEMA) Intrinsically Safe Approval*2
❑ Applicable standard: EN50014, EN50020, EN500284, EN50281-1-1
❑ Certificate: KEMA 02ATEX1274X
❑ 1G/1GD EEx ia IIC T4:
Ui=17.5 V, Ii=360 mA, Pi=2.52 W, Ci=1.76 nF, Li=0 H (FISCO model)
Ui=24.0 V, Ii=250 mA, Pi=1.2 W, Ci=1.76 nF, Li=0 H (Entity model)
❑ 1G/1GD EEx ia IIB T4:
Ui=17.5 V, Ii=380 mA, Pi=5.32 W, Ci=1.76 nF, Li=0 H (FISCO model)
❑ 1D Um=32.0 V:
Tamb(1G): –40 to 60 °C (–40 to 140 °F), Tamb(1D): –40 to 80 °C (–40 to 176 °F),
Tamb(1GD): –40 to 60 °C (–40 to 140 °F), T100 °C (1D, 1GD)
Enclosure: IP65
CENELEC ATEX Type n declaration*2 *5
❑ Applicable standard: EN60079-15
❑ EEx nL IIC T4 Amb. Temp. : –40 to 60 °C (–40 to 140 °F), Enclosure: IP65
❑ Ui=32 V, Ci=1.76 nF, Li=0 H
TIIS Flameproof Approval*3
❑ Certificate: TC15453, TC15452 for option code /BP
❑ Ex d IIC T6 Amb. Temp.: –20 to 60 °C
*1: Applicable for Connections code 3.
*2: Applicable for Connections code 3 and 6.
*3: Applicable for Connections code 1, 3 and 6.
*4: If cable wiring is to be used to a TIIS flameproof type transmitter, do not fail to add the GE Masoneilan
assured flameproof packing adapter.
*5: Applicable for Option code EE.
FVP 110 Fieldbus Valve Positioner Manual
Description
80
Code
KF2
KS25
KN25
JF3

Hide quick links: