Technical Data - Melitta Solo & Perfect Milk Operating Instructions Manual

Table of Contents

Advertisement

Malfunction
The symbols for cleaning
and stand-by
alternately.
Continuous fl ashing of all
buttons.

Technical data

Operating voltage
Power consumption
Pump pressure
Dimensions
Width
Depth
Height
Capacity
Bean container
Water tank
Weight (empty)
Ambient conditions
Temperature
Relative humidity
Reset the appliance to the default settings
You can reset the appliance to the default
settings.
Prerequisite: The appliance must be
ready for operation.
■ To do so, press the on/off button
also press the steam dispensing button
for more than 2 seconds.
→ The appliance has been reset to
default settings.
Operating Instructions: Melitta
Troubleshooting
Cause
The brewing unit is missing
or not properly inserted.
fl ash
The brewing chamber is
overfi lled.
System error
Technical data
and
®
®
Solo
& Perfect Milk | 1830-0618 | 2018-08
Insert the brewing unit properly and
lock.
Switch off the appliance and switch
it on again using the ON/OFF
button
(repeat if necessary) until
standby mode is displayed.
Switch off the appliance and switch
it on again via the ON/OFF button
; if this does not solve the
problem send the appliance to the
service department.
220-240 V, 50/60 Hz
maximum 1400 W
maximum 15 bar
200 mm
455 mm
325 mm
125 g
1.2 l
8,1 kg
10°C to 32°C
30% to 80% (non-condensing)
Overview of default settings:
Default settings
Brewing temperature
Water hardness
Timer for
Auto OFF function
Timer for energy-saving
mode
Technical data
Measure
Medium
Very hard
30 minutes
5 minutes
31

Advertisement

Table of Contents
loading

Table of Contents