General Error List - Bosch Rexroth SHA Series Operating Instructions Manual

Self-contained servo-hydraulic linear axis
Table of Contents

Advertisement

78/91
Bosch Rexroth AG
Troubleshooting
14.3

General error list

Malfunction
Thermal shutdown
Low pressure warning of
accumulator
Malfunction or destruction
of electronic components
Oscillations of the axis
Axis does not move or
moves in an uncontrolled
manner or vibrates
Axis is unstable
Try to determine any changes of the overall system in which the product
is integrated:
Were there any changes to the product's operating conditions or
operating range?
Were there any changes (e.g. retrofit) or repairs carried out on the
complete system (machine/system, electrical system, control) or on
the product? If yes: What were they?
Was the product or machine used as intended?
How did the fault become apparent?
Try to get a clear idea of the cause of error. If possible, ask the direct
(machine) operator.
If you cannot rectify the error, contact one of the contact addresses
which can be found at:
Possible cause
Reduced cooling power
Load cycle outside specifi‐
cation, e.g. break time was
reduced or time in force
control extended
High external system leak‐
age, leakage of gas pres‐
sure accumulator
Defective component, in‐
creased
generation
of
noise
Incorrect wiring
Excessive vibration of the
axis
Incorrect
installation
of
electronics and wiring
Electrical signals are not
received
Wrong gas pressure in the
hydraulic accumulator
Faults in the system
Tab. 14-1:
General error list
Self-contained servo-hydraulic linear axis Type SHA...
http://www.boschrexroth.com
Remedy
Ensure sufficient ventilation
Check the fan (in case of air cooling) for correct connection
In the case of water cooling, check whether the water supply is
connected and whether water actually flows through the cooler.
Adapt cycle
Localize leakage
Contact Bosch Rexroth Service.
Localize leakage
Contact Bosch Rexroth Service.
Check the wiring and the electrical signals with the help of meas‐
uring devices
Contact Bosch Rexroth Service.
Comply with the admissible vibration load
Contact Bosch Rexroth Service.
Use the overview circuit diagrams to check if installation and wir‐
ing are correct
Contact Bosch Rexroth Service.
Check the electronics installation and wiring
Contact Bosch Rexroth Service.
Check gas pressure
Contact Bosch Rexroth Service.
Contact Bosch Rexroth Service.