50/68
Installation
Bosch Rexroth Mellansel AB, Installation and maintenance manual , Hägglunds CB, RE 15302-WA/05.2019
7.4.6
Flushing
To avoid high temperature in the motor case the heat must be removed, because
high temperature gives lower viscosity and that gives reduction in basic rated life /
service life. The motor case must be flushed when the output power exceeds the
max. values.
High temperature in motor case!
Reduction in basic rated life/service life.
▶
Max. power without flushing:
CB 280
CB 400 to CB 1120
For calculation of required flushing, see
Rexroth representative. The flushing oil shall be drained in the normal drainline, see
chapter 7.4.5.
Connect the input flushing line at the lowest drain port, D1 to D4 at opposite side
compared to the drain outlet in order to obtain a cross flushing flow through the
motor, see Fig. 45 and Fig. 46.
CAUTION
120 kW (160 hp)
170 kW (227 hp)
data sheet RE 15302
or contact your Bosch