48/68
Installation
D4
D2
Alternative flushing flow
inlet for flange mounted
motors.
Fig. 45: Horizontal mounting
Bosch Rexroth Mellansel AB, Installation and maintenance manual , Hägglunds CB, RE 15302-WA/05.2019
7.4.5
Draining and venting the motor
Horizontal mounting
When the motor is installed with the shaft in the horizontal plane, the highest of the
four drain outlets D1, D2, D3 or D4 must always be used see Fig. 45.
Drain line must be connected to the tank with a minimum of restrictions, to ensure
that the maximum case pressure is not exceeded.
Drain line connection
D1
Flushing flow inlet
D3
DD00087718