Emerson Liebert HiPulse E Series Communications Manual

Emerson Liebert HiPulse E Series Communications Manual

Modbus / jbus interface

Advertisement

F
F
Ref. Manual: 6313040G-3
U
P
S
U
P
S
U
P
S
C
o
m
m
u
n
C
o
m
m
u
(
M
O
D
B
U
(
M
O
D
B
U
r
o
m
1
6
.
1
t
r
o
m
1
6
.
1
t
S
Y
S
T
E
M
S
Y
S
T
E
M
S
Y
S
T
E
M
i
c
a
t
i
o
n
M
n
i
c
a
t
i
o
n
M
S
/
J
B
U
S
I
n
S
/
J
B
U
S
I
n
o
1
9
.
1
F
W
o
1
9
.
1
F
W
a
n
u
a
l
a
n
u
a
l
t
e
r
f
a
c
e
t
e
r
f
a
c
e
R
e
l
e
a
s
e
)
R
e
l
e
a
s
e
)
(04/07)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Liebert HiPulse E Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Emerson Liebert HiPulse E Series

  • Page 1 Ref. Manual: 6313040G-3 (04/07)
  • Page 3 If you encounter any problems with the procedures contained in this manual you should seek immediate assistance from the EMERSON Sales Office from whom the equipment was purchased. Alternatively, contact the Customer Service & Support department at the address shown below:...
  • Page 4 UPS System: HIPULSE E Communication System Manual (Modbus/Jbus Interface) Page iv...
  • Page 5: Table Of Contents

    Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) CONTENTS: MODBUS/JBUS RTU PROTOCOL UPS NETWORK COMMUNICATION SYSTEM ............................1-1 ENERAL FEATURES SYSTEM FUNCTIONS ............................2-1 PERATOR ANEL MODBUS O ..................2-1 PERATOR OGIC OARD WITH PTION THE EPROM ON THE OPERATOR LOGIC BOARD ............................3-1 HYSICAL OCATION...
  • Page 6 UPS System: HIPULSE E Communication System Manual (Modbus/Jbus Interface) Pagina vi...
  • Page 7: Modbus/Jbus Rtu Protocol Ups Network Communication System

    Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) General Features MODBUS/JBUS RTU PROTOCOL UPS NETWORK COMMUNICATION SYSTEM General features This manual describes the system used for communication between UPSs (or MSS) in the HIPULSE E and the Building Management System (BMS), through networks employing the standard MODBUS/JBUS RTU protocol (in accordance with the specifications provided in the document on the subject, which may be downloaded from the MODICON site at http://www.modicon.com ).
  • Page 8 UPS System: HIPULSE E Communication System Manual General Features (Modbus/Jbus Interface) Page 1-2 (04/07)
  • Page 9: System Functions

    Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) System Functions SYSTEM FUNCTIONS The available system functions for monitoring the UPS are described below. Operator Panel A display and control panel on the front of the UPS permits monitoring of the state of the UPS System, including electrical measurements and possible messages.
  • Page 10 UPS System: HIPULSE E Communication System Manual System Functions (Modbus/Jbus Interface) This page is left blank intentionally Page 2-2 (04/07)
  • Page 11: The Eprom On The Operator Logic Board

    Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) Mechanical Installation THE EPROM ON THE OPERATOR LOGIC BOARD Physical Location The Operator Logic board is located on the inside of the UPS access door (refer to Figure 3-3) or for MSS (see Fig. 3- 4), protected by a metal cover (HIPULSE E only) and connected to the other electronic boards in the UPS\MSS.
  • Page 12 UPS System: HIPULSE E Communication System Manual Mechanical Installation (Modbus/Jbus Interface) Figure 3-2 Location of Operator Logic Board (P/N 4550005F) on the HIPULSE E UPS and connection with the Modbus network (BMS). Page 3-2 (04/07)
  • Page 13 Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) Mechanical Installation Figure 3-3 Location of Operator Logic Board (P/N 4550008I) on the HIPULSE E MSS and connection with the Modbus network (BMS). Page 3-3 (04/07)
  • Page 14: Rs-485 Electrical Connection With Modbus Network

    Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) Electrical installation 3.1.1 RS-485 electrical connection with Modbus network There is a male 3-way X4 connector for connection with the Modbus network (BMS) on the bottom of the board. To make the connection, connect a two-wire shielded cable (supplied by others) to the X4 terminal board of the Operator Logic Board, unless a multipoint connection is required (described in the following paragraph).
  • Page 15: Multipoint Rs-485 Connection

    UPS System: HIPULSE E Communication System Manual Electrical installation (Modbus/Jbus Interface) 3.1.2 Multipoint RS-485 connection To obtain a multipoint RS-485 serial line connection composed of 1 to 32 UPSs, all the devices connected with the Modbus network must be connected with one another in parallel. In this case, in addition to the connection of the Operator Logic X4 with the Modbus network described above, X5 must be used for an additional connection with a cable to provide output to the logic of the other units (refer to Figure 3-6).
  • Page 16 Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) Electrical installation This page is left blank intentionally Page 3-6 (04/07)
  • Page 17: Programming Parameters On The Operator Panel Display

    Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) Programming Operator Panel PROGRAMMING PARAMETERS ON THE OPERATOR PANEL DISPLAY During installation, a series of parameters must be programmed to permit the UPS (or MSS) to function with the MODBUS protocol; this is done with the menu in the Operator Panel display. Note: Modifications to set-up must be made strictly by qualified personnel only.
  • Page 18: Selection Of The Jbus/Modbus Protocols From Operator Panel Menu

    UPS System: HIPULSE E Communication System Manual Programming on Operator Panel (Modbus/Jbus Interface) 4.1.1 Selection of the JBUS/MODBUS Protocols from Operator Panel menu • Default window. This message is displayed in the default window during normal UPS NORMAL OPERATION operation; the message reads ‘ECOMODE’ if the UPS is a single module configuration operating in EcoMode.
  • Page 19 Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) Programming Operator Panel >PROTOCOL xxxxxx< Select PROTOCOL and press ENTER RESET PROTOCOL X The current setting of PROTOCOL xxxxxx will be displayed: it may be ID/CRC JBUS LOC JBUS \ JBUS. Note: with LocJbus the modbus protocol is available on COM PAR JBUS 232 db25 and on 485 there is local slave protocol;...
  • Page 20 UPS System: HIPULSE E Communication System Manual Programming on Operator Panel (Modbus/Jbus Interface) PROTOCOL JBUS RESET PROTOCOL X Select COMmunication PARameters for JBUS and press ENTER. ID/CRC JBUS >COM PAR JBUS< Set user-defined parameters in accordance with the type of protocol. STPB BAUD PAR.
  • Page 21: Technical Description Of The Protocol

    Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) Description of Protocol TECHNICAL DESCRIPTION OF THE PROTOCOL This section provides a detailed description of how the standard MODBUS RTU protocol is implemented in the UPS P/N 4550005F Operator Logic board (or MSS Operator Logic P/N 4550008I). For further information not supplied herein, please refer to the document outlining the standard MODBUS RTU protocol issued by MODICON and available from its Internet site at http://www.modicon.com/techpubs General features of the MODBUS/JBUS RTU protocol...
  • Page 22: Hardware Features Of Communication Protocol

    UPS System: HIPULSE E Communication System Manual Description of Protocol (Modbus/Jbus Interface) Hardware features of Communication Protocol Speed 1200/2400/4800/9600 Baud Start Bits Data Bits Stop Bits 1 or 2 Parity Bits 1 or 2 Parameter Description Parity bit 1 or 2 = [1= None 2 = Even] Software Features of Communication Protocol : The Panel board acts as a Slave, meaning that it stays on standby awaiting commands coming in from the BMS.
  • Page 23: Crc Calculation Notes

    Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) Description of Protocol 5.3.1 CRC Calculation Notes The CRC (Cyclical Redundancy Check) is calculated according to the specifications of the MODBUS RTU protocol using the CRC16 function (refer to Modicon documentation). CRC is a word calculated by the transmitting device and placed at the end of the message sent.
  • Page 24: Commands Entered With The Operator Panel

    UPS System: HIPULSE E Communication System Manual Description of Protocol (Modbus/Jbus Interface) 5.3.3 Commands entered with the Operator Panel This section describes all requests and commands which may be entered with the Operator Panel, specifying syntax and response. The following requests and commands are available: Panel configuration request Function 03 Read Holding Register Panel date and time request...
  • Page 25: Panel Configuration

    Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) Description of Protocol PANEL CONFIGURATION The ‘PANEL CONFIGURATION REQUEST’ command is used to read the system configuration. (*) The same commands apply to UPS system configuration with MSS. Address Meaning Size (bytes) Range / Resolution Format 40001...
  • Page 26: Ups\Mss Time

    UPS System: HIPULSE E Communication System Manual Description of Protocol (Modbus/Jbus Interface) UPS\MSS TIME The ‘UPS time request’ command is used to read the current time on the UPS. (*) The same commands apply to UPS system configuration with MSS. Address Meaning Size (bytes)
  • Page 27: Alarm Status

    Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) Description of Protocol ALARM STATUS Range / Address Meaning Size (bytes) Format Resolution 40030 Alarm 1- 16 HEX note 1 40031 Alarm 17- 32 HEX note 2 40032 Alarm 33- 48 HEX note 3 40033 Alarm 49- 64...
  • Page 28 UPS System: HIPULSE E Communication System Manual Description of Protocol (Modbus/Jbus Interface) Note Alarms 32 through 47 Meaning UPS MSS bit 0 INVERTER: BLOCK bit 1 INV: CURRENT LIMIT bit 2 INV: OVERTEMPERATURE bit 3 INV: UNSYNCHRONIZED bit 4 INV: OVERVOLTAGE bit 5 INV: UNDERVOLTAGE bit 6...
  • Page 29 Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) Description of Protocol Note Alarms 64 through 79 Meaning UPS MSS Bit 0 BACKFEED FAULT Bit 1 SYNCHRO. INHIBITED Bit 2 OVERLOAD PRESENT Bit 3 OVERLOAD SHUTDOWN Bit 4 RES/IND OVERLOAD PROTECTION *NOTE Bit 5 PEAK CURRENT PROTECTION...
  • Page 30 UPS System: HIPULSE E Communication System Manual Description of Protocol (Modbus/Jbus Interface) Page 5-10 (04/07)
  • Page 31: Measurements

    Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) Description of Protocol MEASUREMENTS This command may be used to read current UPS\MSS status in terms of electrical quantities. Range / Address Meaning Size (bytes) Format UPS MSS Resolution 40040 Vout L1-L2 1 Volt 40041 Vout L2-L3...
  • Page 32 UPS System: HIPULSE E Communication System Manual Description of Protocol (Modbus/Jbus Interface) Note Measurements not present on the MSS In certain cases, measurements of given quantities have no significance when running on MSS, but are significant when running on UPS. In this case, if the RTU Jbus/Master Modbus requests these measurements the value returned will be 0xFFFF.
  • Page 33: Programming Parameters

    Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) Description of Protocol PROGRAMMING PARAMETERS Address Meaning Range / Resolution Format UPS MSS SIZE (BYTES) 40080 Rated voltage Rotating HEX note 1 40081 Lower limit on 00:99 (V rated input voltage 40082 Upper limit on 00:99 (V...
  • Page 34 UPS System: HIPULSE E Communication System Manual Description of Protocol (Modbus/Jbus Interface) UPS Power 0x0 = 30 kVA 0x1 = 40 kVA 0x2 = 60 kVA 0x3 = 80 kVA 0x4 = 120 kVA 0x5 = 160 kVA 0x6 = 200 kVA 0x7 = 300 kVA 0x8 = 400 kVA 0x9 = 500 kVA...
  • Page 35 Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) Description of Protocol 5.10 EVENT HISTORY IN SELECTED BUFFER This command may be used to read messages stored in the <Event-History> records. Position Meaning Size (bytes) Values Format UPS MSS 40150 ALARM HOUR 0 : 23 ASCII...
  • Page 36 UPS System: HIPULSE E Communication System Manual Description of Protocol (Modbus/Jbus Interface) MSS status: bit 0 MSS status (Inverter side) 0 = Inverter OFF 1 = Inverter ON bit 1 MSS status (Mains side) 0 = Mains OFF 1 = Mains ON bit 2 to 15 not in use Note Measurements with Rotating values...
  • Page 37 Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) Description of Protocol 5.11 FUNCTION 06: LIST OF EVENT HISTORY COMMANDS Position Meaning Size (bytes) Values Format UPS MSS 40200 Alarm History Commands Note 1 Note value = 0x0101 Command to set pointer to last Alarm History block value = 0x5555 Command to set pointer to previous Alarm History block value = 0xAAAA...
  • Page 38: Function 06: List Of Machine Functioning Commands

    UPS System: HIPULSE E Communication System Manual Description of Protocol (Modbus/Jbus Interface) 5.12 FUNCTION 06: LIST OF MACHINE FUNCTIONING COMMANDS Position Meaning Size (bytes) Values Format UPS MSS 40201 Inverter Command Note 1 40202 Rectifier command Note 2 e 7 40203 Mains command Note 3...
  • Page 39: Function 06 And 16: List Of Date And Time Commands

    Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) Description of Protocol 5.13 FUNCTION 06 AND 16: LIST OF DATE AND TIME COMMANDS 5.13.1 SET TIME COMMANDS Position Meaning Size (bytes) Values Format UPS MSS 40020 UPS HOUR (*) 0 : 23 ASCII 40021 UPS MINUTES (*)
  • Page 40: Error Response Message Format

    UPS System: HIPULSE E Communication System Manual Description of Protocol (Modbus/Jbus Interface) 5.14 ERROR RESPONSE MESSAGE FORMAT Message Meaning Size (Bytes) Values Format SLAVE Panel board address 0x01 - 0xF7 Function Code FCT or 0x80 Error Code Note 1 Checksum Note 1: Error Code 01 unknown function code...
  • Page 41: Map Of Jbus/Modbus Rtu Addresses

    Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) Description of Protocol 5.15 MAP OF JBUS/MODBUS RTU ADDRESSES: Address Meaning Size Fc16 Can. Prg. UPS MSS 40001 UPS\MSS power 40002 Panel software release 40004 Logic software release 40006 Configuration 40007 UPS\MSS status 40008 Alarm status...
  • Page 42 UPS System: HIPULSE E Communication System Manual Description of Protocol (Modbus/Jbus Interface) Address Meaning Size Fc16 Can. Prg. UPS MSS 40080 Rated voltage 40081 Lower limit on rated input voltage 40082 Upper limit on rated input voltage 40083 Lower limit on rated output voltage 40084 Upper limit on...
  • Page 43 Communication System Manual UPS System: HIPULSE E (Modbus/Jbus Interface) Description of Protocol Address Meaning Size Fc16 Can. Prg. UPS MSS 40150 ALARM HOUR 40151 ALARM MINUTES 40152 ALARM SECONDS 40153 ALARM DAY 40154 ALARM MONTH 40155 ALARM YEAR 40156 UPS\MSS status (ALARM) 40157 Alarm status 40158...
  • Page 44 UPS System: HIPULSE E Communication System Manual Description of Protocol (Modbus/Jbus Interface) Address Meaning Size Fc16 Can. Prg. UPS MSS 40200 Alarm History command 40201 Inverter command 40202 Rectifier command 40203 Mains command 40204 Battery test command 40205 Battery charge command 40206 Alarm reset command Legend :...