BAMO A1, A2 60-500A
Default setup
switch on mains
LED BTB
bright green
command value 0V
enable drive
Motor stands still
or runs smooth slow
increase comm.value
up to10%
Motor runs smooth
with ca. 10%
adjust speed to 0
with trimmer “Offset”
adjust speed with
max
poti n
increase comm.value
to 100%
Motor runs smooth
with ca. 100%
adjust current limits
peek current with I
and
steady current I
motor data
“Getting Started”
finished
optimize drive
fill in protocol
26
to 10%
max
,
to
switch off mains
clear failure
LED BTB glim green
overtemperature
LED "fault" red bright
short in motor connection
motor speeds up
tacho connection
mixed up or
interruped
Motor stands still
check comm.value
check motor connection
motor runs jerky
2
reduce amplification X
Speed cannot be adjusted
resistor R23 wrong
mains voltage too low
current limit too low