BAMO A1, A2 60-500A
External current limitation
voltage source for external current limit
+10V/10mA
GND
Current limit input
maximum input voltage +10V
input resistance 10 kW
internal attenuation with potentiometer I
relay contacts: gold- or reed contacts
switch S1, contact 2 = OFF (see page 17)
Connection
current limit
Adjustment range
0 ... + 5V
0 ... +10V
internal overcurrent control
Int.supply
Caution:
case of internal current limit adjustment
switch S1
>>>
(see page 19)
14
X1:13
X1:7
max
X2:13 (signal)
X1:7 (GND)
>>>
0 up to 100% device command current
>>>
0 up to 200% device command current
>>>
max. 5sec.
CNC/PLC
contact 2 = ON
Comm.value current