WOERNER GMF-E Translation Of The Original Instructions

Reciprocating pump

Advertisement

Quick Links

Reciprocating pump
GMF-E
Translation of the
Original instructions
Version EN 06/2016
Original instructions GMF-E
Page 1 of 32
B0343

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GMF-E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for WOERNER GMF-E

  • Page 1 Reciprocating pump GMF-E Translation of the Original instructions Version EN 06/2016 Original instructions GMF-E Page 1 of 32 B0343...
  • Page 2 This document shall neither be transferred to third parties nor copied. content must neither commercialized communicated, if not explicitly allowed. Violating the before mentioned will cause claim for indemnification. All rights reserved. Original instructions GMF-E Page 2 of 32 B0834...
  • Page 3: Table Of Contents

    7.4.1 Motor ........................21 Start-up........................21 Putting out of operation ................... 23 8. Operating manual ......................24 Trouble shooting and remedy ................. 24 Refilling the container ..................... 24 Powering down ....................... 25 Original instructions GMF-E Page 3 of 32 B0834...
  • Page 4 10. Accessories ......................... 28 11. Return to manufacturer ....................29 12. Disposal ........................31 13. Appendix ........................31 13.1 Content of the declaration of conformity..............31 13.2 Declaration of Conformity ..................32 Original instructions GMF-E Page 4 of 32 B0834...
  • Page 5: Important Information On This Operating Manual

    As owner and user of this pump unit, you are obliged reading and understanding this operating manual, in particular the chapter “Safety instructions”. It is your safety that is dealt with. In case of question and doubt, please get in contact with WOERNER. 1.3 Questions: What to do? If questions arise, which you cannot solve with this operating manual, do not hesitate asking WOERNER for support.
  • Page 6: Site Of Operation

    Important! Instructions for use and other useful information that facilitate usage of the product according to its design. Danger! Immediately threatening danger by electric current that may lead to heavy body injuries. Original instructions GMF-E Page 6 of 32 B0834...
  • Page 7: Identification

    2. Identification 2.1 Product mark and type designation Piston pump unit of the manufacturer Eugen Woerner GmbH & Co. KG Product type: GMF 2.2 Product version Version from the year of production 2015 2.3 Product denomination The identification plate has been attached to the side of the pump case and informs on:...
  • Page 8: Product Description

    90% Noise level : <70 dB(A) Physical environment If the equipment is planned to be operated at a level higher than 1,000 m above sea level, consult the manufacturer, in every case. Original instructions GMF-E Page 8 of 32 B0834...
  • Page 9: Use According To Design

    (1013 mbar) at the admissible maximum temperature, also highly flammable or explosive media as well as foodstuff! Important! Please consider the safety specification sheets of the applied substances as well! Original instructions GMF-E Page 9 of 32 B0834...
  • Page 10: Technical Data

    6: 330 bar  Motor electrical data Mains voltage 220/380 V Frequency 50 Hz Synchronous speed 1350 min Power 0,4 kW  Protection system DIN EN 60529 IP55  Thermal category Original instructions GMF-E Page 10 of 32 B0834...
  • Page 11: Dimensions

    4.3 Dimensions Original instructions GMF-E Page 11 of 32 B0834...
  • Page 12: Description Of Function

    The function of the pump elements will be explained later. An agitator is linked with the pump shaft forcing the lubricant to the suction borehole of the pump elements to comminute air bubbles. Original instructions GMF-E Page 12 of 32 B0834...
  • Page 13: Pump Elements

    As for precise adjustment to a defined volumetric displacement per stroke, a volumetric prove-measurement has to be taken. The pump elements are delivered adjusted to maximum volumetric displacement.  Turn in the plug screw 7. Original instructions GMF-E Page 13 of 32 B0834...
  • Page 14: Safety Instructions

    For planning and inspection of the work, specialists with product-specific training are responsible. 6.3 Safety devices From mechanical aspect, the pump unit is inherently safe due to its design. The pump unit must be operated only with the cover of the container closed. Original instructions GMF-E Page 14 of 32 B0834...
  • Page 15: Reservoir Lid

    In normal use both fasteners must be closed. If it´s necessary to open the lid it is mandatory to follow the instructions below. Description Locking hook Locking lug Safety latch (Locked) Safety cover Locking lever Original instructions GMF-E Page 15 of 32 B0834...
  • Page 16 After safety latch is unlocked, lift the locking lever and release the locking lug from the locking hook to fully unlock the fastener. Step 3: Repeat step 1 and 2 for the second fastener. Original instructions GMF-E Page 16 of 32 B0834...
  • Page 17 Repeat step 1 for the second fastener Warning! Try if safety latch is snapped in by pulling the locking lever. Lifting the locking lever is not possible if the safety latch is in the locked position Original instructions GMF-E Page 17 of 32 B0834...
  • Page 18: Accident Prevention

    Referring to experience, improper use may include, for example:  Supply of highly flammable or explosive media  Supply of media, which are able reacting with materials the pump unit has been made  Supply of foodstuff Original instructions GMF-E Page 18 of 32 B0834...
  • Page 19: General Safety Regulations And Duties

    If damage to persons, equipment, environment and assets occurs due to ignoring this operating manual regardless if intentionally or unintentionally, WOERNER shall not be held responsible. No claim for warranty will be accepted. This is also true for any consequential damage.
  • Page 20: Transport, Installation, Start-Up And Putting Out Of Operation

    In addition, make sure that the mounting surface is plane. As for the installation the pump unit take necessary prevent measures to protect the unit from unintentional shocks. Drilling pattern: Original instructions GMF-E Page 20 of 32 B0834...
  • Page 21: Power Supply And Powering-Up

    Observe the safety instructions in section “Power supply and Important! powering-up”. Actions to be taken for start-up: a) Filling the pump unit with lubricant Operate the pump unit with clean oil or grease from OEM-containers only! Original instructions GMF-E Page 21 of 32 B0834...
  • Page 22 Warning! Pump pressure above the admissible operating pressure of 350 bar may lead to destruction of the installation and health- hazardous situations! Original instructions GMF-E Page 22 of 32 B0834...
  • Page 23: Putting Out Of Operation

    7.6 Putting out of operation The pump unit is put out of operation by switching-off and deinstalling from the external power supply. Original instructions GMF-E Page 23 of 32 B0834...
  • Page 24: Operating Manual

    If the above described trouble shooting guide should not successfully work and the proposed remedy does not help eliminating the fault to restore the proper function of the pump unit, please get in contact with WOERNER. 8.2 Refilling the container If the equipment is operating with oil, refill directly into the container.
  • Page 25: Powering Down

    8.3 Powering down Powering down is by disconnecting the pump unit from the power supply. Original instructions GMF-E Page 25 of 32 B0834...
  • Page 26: Cleaning, Servicing, Fault Remedy And Repair

    "Safety instructions". Take effective measures to avoid injuries. Important! Consider also the maintenances instructions for the single components of the respecting operating manuals collected in the annex. Original instructions GMF-E Page 26 of 32 B0834...
  • Page 27: Inspection Chart

     Screw in the pump element. Fill the borehole of the pump element supporting the displacing pistons with grease to facilitate both assembly and start-up. For any further repair, please contact WOERNER. Original instructions GMF-E Page 27 of 32 B0834...
  • Page 28: Accessories

    1 piece per pump each The GMF-E is a part of the GMF family, please refer therefore also data sheets P9002 for more information. Please also refer to the GMF-E datasheet P0834...
  • Page 29: Return To Manufacturer

    Before shipping the product, make sure that the following measures have been taken:  Empty and clean the product.  Plug all openings.  Pack the product safely and attach complete shipping documents.  Attach the declaration of harmlessness. Original instructions GMF-E Page 29 of 32 B0834...
  • Page 30 The respective safety sheets have been attached. Date of return: Name, position: Phone number: Date, signature: Firm stamp: Appendices: Safety data sheet Original instructions GMF-E Page 30 of 32 B0834...
  • Page 31: Disposal

    In addition, the machine complies with all provisions of the directives 2004/108/EG. The following harmonised standards apply: DIN EN ISO 12100 DIN EN 60204-1 DIN EN ISO 4413 In charge for documentation: Stefan Tiederle Original instructions GMF-E Page 31 of 32 B0834...
  • Page 32: Declaration Of Conformity

    13.2 Declaration of Conformity Original instructions GMF-E Page 32 of 32 B0834...

This manual is also suitable for:

123456.10.001

Table of Contents