5

Installation

5.1

Notes on safety for the installation

After carefully cleaning all around the area where the burner will
be installed, and arranging the co rrect lighting of the environ-
ment, proceed with the installation operations.
All the installation, maintenance and disassembly
operations must be carried out with the electricity
supply disconnected.
DANGER
The installation of the burner must be carried out
by qualified personnel, as indicated in this manual
and in compliance with the standards and regula-
tions of the laws in force.
WARNING
5.2

Handling

The packaging of the burner includes a wooden platform, so it is
possible to move the burner (still packaged) with a transpallet
truck or fork lift truck.
The handling operations for th e burner can be
highly dangerous if not carried out with the great-
est attention: keep any unauthorised people at a
distance; check the integrity and suitableness of
WARNING
the available means of handling.
Check also that the area in which you are working
is empty and that ther e is an adequate escape
area (i.e. a free, safe area to which you can quick-
ly move if the burner should fall).
During the h andling, keep the load at not more
than 20-25 cm from the ground.
After positioning the burner near the installation
point, correctly dispose of all residual packaging,
separating the various types of material.
Before proceeding with the installation operations,
CAUTION
carefully clean all around the area where the burn-
er will be installed.
20011755
Installation
5.3

Preliminary checks

Checking the consignment
After removing all the packaging, check the integ-
rity of the contents. In the event of doubt, do not
use the burner; contact the supplier.
CAUTION
The packaging elements (wooden cage or card-
board box, nails, clips, plastic bags, etc.) must not
be abandoned as they a re potential sources of
danger and pollution; they should be collected
and disposed of in the appropriate places.
Checking the characteristics of the burner
D9370
Check the identification label of the burner, showing:
the model (see A in Fig. 4) and type of burner (B);
the year of manufacture, in cryptographic form (C);
the serial number (D);
the electrical input power (E);
the types of fuel used and the relative supply pressures (F);
the data of the burner's minimum and maximum output pos-
sibilities (G) (see Firing rate)
The output of the burner must be within the boil-
er's firing rate;
WARNING
A burner label that has bee n tampered with, re -
moved or is missing, along with anything else that
prevents the definite identification of the burner
makes any installation or maintenance work diffi-
WARNING
cult.
10