What To Do If - RADEMACHER RolloTron Comfort 1623 45 19 Translation Of The Original Operating And Assembly Manual

Electronic roller shutter belt winder
Hide thumbs Also See for RolloTron Comfort 1623 45 19:
Table of Contents

Advertisement

i

19. What to do if... ?

Fault
... the RolloTron Comfort indicates no
functions?
... the RolloTron Comfort no longer reacts in the
morning at the configured switching time?
... the roller shutters no longer stop at the configured
end points?
... the roller shutters stop as soon as the control button
is released?
... the RolloTron rotates in the wrong direction?
Possible cause / solution
Check the power supply incl. connecting cable and plug.
The electronic system switched off the drive after closing the roller
shutters because the deflection roller stopped turning. This is the case if:
a) The [ Down ] button was pressed for an excessive period of time
during the configuration process for the lower end point. The
roller shutter slats are closed, but the belt continued to wind and
is no longer tight on the deflection roller.
b) The lower end point is displaced due to elongation of the belt.
The belt may never be slack.
Reconfigure the lower end point (see page 55) and ensure that
the belt remains tight to the deflection roller.
In doing so, the deflection roller must turn evenly.
The end points may be displaced due to elongation of the belt.
Readjust the end points, see page 55.
The end points are not configured. Configure the end points, see
page 55.
Possibly the belt is wrapped around the reel incorrectly, see page 21.
EN
65

Advertisement

Table of Contents
loading

Table of Contents