3-5-9.
White
Clip
Adjustment
Object:
Grayscale
chart
Equipment:
Waveform
monitor
To
be
extended:
PR-111
board
Preparation:
Set
the
BARS
WB
switch
on
the
side
of the camera
to 3200°K.
Set
the
GAIN
switch
to
OdB.
Adjustment:
1. Adjust
the
zoom
control
so
that
the
gray-
scale
chart
frame
touches
the
underscanned
picture
frame
on
the
monitor.
(TUTTI
ajc
Monitor
Screen
2.
Set
the
iris
control
to OPEN.
3. Adjust
ORV9/PR-111
board
so
that
the
white
peak
level
is
800+15mV
on
the
waveform
monitor.
4.
Adjust @RV1O
and @RV11/PR-111
board
several
times
so
that
the
carrier
leakaga
of
the
white
peak
level
is minimized.
RV4 tp7
Hs
QO
@Q?
es
sn?
©
800 + 15mv
| RV3 tps
ees
7
o
ase
CLIP
©
TPS
RVS
rer
6
TPI2
RVIt
RV7
RvB
.
®t
he
6
8
RV14
TPB
BLACK
TRACKING
R PED
et
@
Ne
PP
QQ)a
Ve RVi2
RVI6
PR-111 BOARD (COMPONENT
SIDE)
3-20
DXC-325P (EK)