LOCATION - GENERAL

• Access: For emergencies and maintenance the pump must be
easily accessible.
• Protection: The iBolt must be located in a dry, frost free area. The
iBolt must not be installed in a loft space.
• Ventilation: Ensure an adequate air flow to cool the iBolt.
Separate the iBolt from other appliances that generate heat.
• Water retention: Site the unit in a location where in the unlikely
event of a water leak, any spillage is contained or routed to avoid
electrics or areas sensitive to water damage.
• Ambient temperature: The iBolt must be sited in a location where
the ambient temperature does not exceed 30°C.
• Isolating valves: Separate system isolating valves (non restrictive)
must be fitted to allow easy pump service. Isolating valves must
be mounted where specified to allow the system isolation and
removal of the iBolt if needed. See Section 9 for installation
details.
• Preferred iBolt location: The preferred iBolt location is on a
smooth level floor of sufficient strength to support the weight of
the iBolt close to the water source.
The iBolt must not be installed in a loft space.
It must also be considered that the noise and vibration from the
iBolt may be transmitted through the structure the iBolt is sited
on.