  • Page 2: Table Of Contents

    Evo Control 17 & 25 Manual Contents 1. Introduction _________________________________________________________________________________ 2 2. Unit Specifications ____________________________________________________________________________ 2 2.1 Unit Structure _____________________________________________________________________________ 2 2.2 Dimensions _______________________________________________________________________________ 3 2.3 Technical Data ____________________________________________________________________________ 4 3. Safety Instructions ____________________________________________________________________________ 5 4. Installation __________________________________________________________________________________ 6 4.1 Application for Air-Con______________________________________________________________________ 6 4.2 Application for Air-Con and Super Heater (for Hot Water) __________________________________________ 6...
  • Page 3: Introduction

    Evo Control 17 & 25 Manual 1. Introduction This manual contains all the necessary information in regard to the installation, troubleshooting, operation and maintenance of this unit. Ensure instructions in this manual are adhered to at all times. Failing to comply with these recommendations will invalidate the warranty.
  • Page 4: Dimensions

    Evo Control 17 & 25 Manual 2.2 Dimensions Evo Control 17 Evo Control 25...
  • Page 5: Technical Data

    Evo Control 17 & 25 Manual 2.3 Technical Data Evo Control 17 Evo Control 25 13.5 19.5 Cooling Capacity Btu/h 46000 67000 17.0 25.0 Heating Capacity Btu/h 58000 85000 Cooling Power Input Heating Power Input Running Current (Cooling/Heating) 20.4/17.8 12.1/10.3...
  • Page 6: Safety Instructions

    Evo Control 17 & 25 Manual 3. Safety Instructions Installation, repairs and maintenance of this unit must be performed by a qualified technician. • • Any wiring must comply with local electrical regulations. • Ensure that the electrical supply corresponds to the specification indicated on the unit’s makers plate before proceeding with the connection in accordance with the wiring diagram supplied.
  • Page 7: Installation

    Evo Control 17 & 25 Manual 4. Installation 4.1 Application for Air-Con 4.2 Application for Air-Con and Super Heater (for Hot Water)
  • Page 8: Location Of Install & Minimum Clearances

    Evo Control 17 & 25 Manual 4.3 Location of Install & Minimum Clearances The heat pump can be installed onto a concrete basement by using expansion screws, or onto a steel frame with rubber feet which can be placed on the ground or the roof. Ensure that the unit is placed horizontally.
  • Page 9: Transit

    Evo Control 17 & 25 Manual 4.6 Transit If the unit needs to be hung up during installation, an 8-metre cable is required. There must be a soft material between the cable and the unit to prevent damage to the heat pump cabinet WARNING: Do not touch the heat exchanger of the unit with fingers or objects.
  • Page 10: Operation

    Evo Control 17 & 25 Manual 5. Operation 5.1 Main Controller Interface Button Name Function Press this button to start up/shut off the unit, cancel current operation or go back to ON/OFF previous interface. HELP Press this button to check button function of system state.
  • Page 11: Switching Modes

    Evo Control 17 & 25 Manual 5.2.3 Switching Modes At the main interface, you can switch between the modes of cooling, economic heating, heating & rapid heating by pressing . Example: Switch from Cooling mode to Economic Heating Note: The operation of mode is invalid if the unit you purchase is heating only or cooling only.
  • Page 12: Timer Settings

    Evo Control 17 & 25 Manual 5.2.7 Timer Settings Four timer periods can be set according to your needs. From the main interface, press to enter the timer setting, press DOWN to select Timer, then press to enter the timer setting interface. The process is much the same as adjusting the Clock settings. To cancel and return to the previous menu, press the ON/OFF button.
  • Page 13: Keyboard Lock

    Evo Control 17 & 25 Manual 5.2.7.2 Daily Timer The Daily Timer allows you to apply your timers to particular days of the week. • OFF means that the unit will not run on that day. • ON means the system will be running for a whole day.
  • Page 14: Troubleshooting

    Evo Control 17 & 25 Manual 6. Troubleshooting 6.1 Failure Codes of the Controller – Evo Control 17 Malfunction Display Indicator Reason Resolution Power on Normal working Inlet temp. sensor failure 1 on 1 off The temp. sensor is broken or Check or change the temp.
  • Page 15 Evo Control 17 & 25 Manual Communication Failure Communication failure Check the wire connection between between wire controller and remote wire controller and main board main board 6.2 Failure Codes of the Controller – Evo Control 25 Malfunction Display Reason...
  • Page 16 Evo Control 17 & 25 Manual 6.3 System Failures (Both Models) FAILURE POSSIBLE CAUSES SOLUTIONS Wrong power supply Shut off the power and check power supply Heat pump cannot be Power supply cable loose Check power cable and correct the connection...
  • Page 17: Appendix

    Evo Control 17 & 25 Manual 7. Appendix 7.1 Install Sketch Map Especial Installation (expandable water tank) Legend explanation 1. Main Unit 11. Drain 2. Fan Coil 12. Filter 3. Rubber Flexible Connection 13. Two-way Valve 4. Thermometer 14. Three-way Valve 5.
  • Page 18: Installation Of Automatic Filled-Water

    Evo Control 17 & 25 Manual 7.2 Installation of Automatic Filled-Water 1. When the automatic filled-water valve is installed, the arrowhead orientation of inlet water must accord with the orientation of the valve 2. Automatically filled-water has been adjusted in advance to 1.5bar 3.
  • Page 19: Assistant Heat Source Connection

    Evo Control 17 & 25 Manual 7.4 Assistant Heat Source Connection Unit provides the connection of assistant heat source which is not only for the gas-fired boiler, but also the electronic boiler or warm-net pipe for city accordingly. 1. Water chiller and heat pump + assistant gas-fired boiler 2.
  • Page 20: Pcb Connection

    Evo Control 17 & 25 Manual 7.6 PCB Connection 7.6.1 PCB Connection of Evo Control 17 Symbol Meaning No. Symbol Meaning AC-L Live line DI 08 Electric heater overload protection input AC-N Null line DI 09 Compressor 1 overload protection input...
  • Page 21 Evo Control 17 & 25 Manual 7.6.2 PCB Connection of Evo Control 25 Symbol Meaning No. Symbol Meaning Live line DI 11 System protection signal Null line AI 01 Water input temperature input RO 01 Compressor 1 output(220VAC) AI 02...
  • Page 22: Cable Specifications

    Evo Control 17 & 25 Manual 7.7 Cable Specifications Single Phase Unit Nameplate maximum Phase Line Earth Line Creepage Protector Signal Line current No more than 10A 2 x 1.5mm 1.5mm 10 ~ 16A 2 x 2.5mm 2.5mm 16 ~ 25A...
  • Page 23: Maintenance

    Evo Control 17 & 25 Manual 8. Maintenance Check the water supply and air vent frequently to avoid any lack of water, or air in the water Loop. Clean the water filter according to a schedule to keep good water quality. Lack of water and dirty water can damage the unit. The heat pump will start the water pump every 72 hours when it is not running to keep it from freezing.
  • Page 24: Warranty

    Warranty Registration EvoHeat highly recommend customers to complete their warranty details online to ensure efficient warranty claim processing. To register your warranty, scan our QR Code or head to our website and fill in the Warranty Registration Form: https://evoheat.com.au/warranty-registration/...