EvoHeat unit. Instructions in this manual must always be followed. Failure to comply with these recommendations will invalidate the warranty. Should you have any questions or require technical support, call the EvoHeat office on 1300 859 933 to speak to our team.
Page 3 Evo Max Series Manual 2. Dimensions Evo Max A (L) B (W) C (H) 1175 1605 1267 Evo Max A (L) B (W) C (H) 1195 1900 Evo Max A (L) B (W) C (H) 1930 1050 1980...
Page 4 Evo Max Series Manual 3. Safety Instructions • Installation, repairs and maintenance of this unit must be performed by a qualified technician. • Any wiring must comply with local electrical regulations. • If any abnormal instances occur or a strange smells, the unit must be shut off by the power supply.
Page 5 Evo Max Series Manual 4. Installation 4.1 Transit When transporting the unit, ensure the unit is kept standing upright. Laying the unit down may damage internal parts. If the unit needs to be hung up (such as for lifting with a crane) use the special lifting hole (hook) on the base of the unit with an 8 metre cable.
Page 6 Evo Max Series Manual 4.4 Plumbing Try to reduce the resistance to the water from the piping. • The piping must be clear and free from dirt and blockage. A water leakage test must be carried out to •...
Page 7 Evo Max Series Manual 4.6. Initial Start-Up Prior To: Check the indoor unit, make sure that the pipe connection is done correctly and that the relevant valves are open. Check the water loop to ensure that there is enough water inside of the expansion tank, that the water supply is good and that the water loop has no air in it and is full of water.
Page 8 Evo Max Series Manual 5. Operation 5.1 The Controller Turn the unit on or off. When the unit ON/OFF is on, the button will be red. MODE Switch modes TEMP. Enter the temperature setting menu. SETTING FAST Press this to begin rapid heating.
Page 9 Evo Max Series Manual 5.2.4 Fast Heating Mode While the unit is in heating mode, press the FAST HEATING button to enable the rapid heating function. 5.2.5 Setting a Timer You can set a customised start-up and shutdown timer for your unit.
Page 10 Evo Max Series Manual 6. Troubleshooting Fault Protect/fault Reason Elimination methods Display Inlet Temp Sensor Fault The temp. Sensor is broken or short circuit Check or change the temp. sensor Outlet Temp Sensor Fault The temp. Sensor is broken or short circuit Check or change the temp.
Page 11 Evo Max Series Manual 7. Appendix 7.1 Parameter List Meaning Default Remarks Cooling target temperature set point 12°C Adjustable Heating the target temperature set point 40°C Adjustable Hot Water target temperature set point 55°C Adjustable 7.2 Cable Specifications...
Page 12 Evo Max Series Manual 7.4 Controller Interface Diagram Sign Meaning AI/DI01 Water input temperature AI/DI02 Water output temperature AI/DI03 System 1 coil temperature AI/DI04 Ambient temperature AI/DI05 System 1 suction temperature AI/DI06 System 1 antifreeze 1 temperature/ system 1 coil temperature 2...
Evo Max Series Manual 8. Maintenance It is recommended that you get your EvoHeat unit serviced once a year by your local certified air conditioning or refrigeration technician. If your unit is located in a coastal area, more frequent maintenance may be necessary.
REGISTER YOUR WARRANTY EvoHeat highly recommend customers complete their warranty details online to ensure efficient warranty claim processing. To register your warranty, scan our QR Code or head to our website and fill in the Warranty Registration Form: https://evoheat.com.au/warranty-registration/...
Need help?
Do you have a question about the EVO MAX Series and is the answer not in the manual?
Questions and answers