The data above is based on the Evo heat pump only, it does not include auxiliary devices. Product specification information provided above is correct at the date of printing, this data may change without notice. Please speak with an EvoHeat Specialist for the most current product specifications.
Fusion-i A (L) B (W) C (H) 7, 9 & 12 1004 Fusion-i 16 Fusion-i A (L) B (W) C (H) 1046 764.5 Fusion-i 19 Fusion-i A (L) B (W) C (H) 1161 861.5 96.5 info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
2. Use plumbing tape and ensure the ‘O’ ring is in position when sealing. 3. Install a 3-way valve at the cold-water inlet and create a bypass by connecting a “T” piece to the heated line. 4. Make the plumbing connections and brace pipework where necessary. info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
Page 6
NOTE: The water pump must be running and water circulating through the heat pump for the system to operate. 1. Turn on your water filter pump and check for water leaks and verify flow to and from the pool. 2. Turn on the electrical power supply to the EvoHeat unit. 3. Press the ON/OFF button of the controller for half a second, the heat pump will start within 60 seconds 4.
Do not use any means to accelerate the defrosting processor or to clean The unit is equipped with other than those recommended by EvoHeat. an over-load protection The unit must be stored in a room without any continuously operating system.
5.1 System Installation Upon receiving the unit, check the packaging for any obvious signs of damage. Inform EvoHeat immediately if there is any evidence of rough handling. When the heater has been removed from the packaging check the refrigerant gauge on the front panel of the unit.
5.4 Adequate Water Flow All EvoHeat heat pumps have a factory pre-set internal water flow switch. If there is insufficient water flow the unit will not operate. It is VITAL that that there is sufficient water flow to the unit. Incorrect water flow can cause a loss of efficiency and possible damage to the unit.
The electrical wiring diagram is affixed to the inside of the front panel or at the back of this manual. 5.10 Initial Start-Up Refer to the Quick Start Guide in this manual for instructions on the initial start-up and commissioning of the unit. info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
For heating, the upper numbers will be a lower degree as it is bringing in cold water, while the lower numbers will be higher as it is expelling warmer water. For cooling, the upper value will be a higher temperature than the lower value. info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
Page 11 Fusion-i Series Manual 6.2 Operating Functions EvoHeat have developed a YouTube Channel with video walkthroughs of the different controller functions. Scan the QR code or head to our channel to view the videos we have available https://www.youtube.com/evoheat 6.2.1 Startup & Shutdown Only from the main screen, the unit can be turned on or off.
OFF1, ON2 or OFF2. To set the time, follow the same process as changing the system time to adjust values. On at 9:20 NOTE: You You will need to set both an ON & OFF Time if using this function info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
When the MUTE icon is flashing, it is under silent status. When there is no MUTE icon, the timing silent has not been set. To cancel the Timing Silent Function, follow the process in 6.2.5.2 Cancelling a Timer. info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
When a failure occurs, the controller will display a code according to the reason of the fault (See 7. Troubleshooting for definition of the codes). From the main interface, press the ON/OFF button to view the faults. If there are multiple faults, use the UP and DOWN keys to view others. info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
Communication Fault (speed Speed control module and main board E081 Check the communication connection control module) communication fail Coil2 Temp. Sensor Fault The temp. sensor is broken or short circuit Check or change the temp. sensor info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
Check and adjust the current measurement Check whether the chip is damaged EEPROM Error Warn MCU error Replace the chip Check the V15V input voltage in range V15V over/undervoltage fault The V15C is overload or undervoltage 13.5v~16.5v or not info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
Adjustable Automatic target temperature set point 27°C Adjustable 8.3 Refrigerant Saturation Temperature Pressure (MPa) Temperature (R410A)(°C) -51.3 Temperature (R32)(°C) -52.5 29.5 33.3 38.7 Pressure (MPa) Temperature (R410A)(°C) Temperature (R32)(°C) 46.5 49.5 53.5 67.5 72.5 77.4 info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
9. Maintenance 9.1 F.A.Q It is recommended that you get your EvoHeat unit serviced once a year by your local certified air conditioning or refrigeration technician. If your unit is located in a coastal area, more frequent maintenance may be necessary.
Prior to recharging the system, it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site. The safety wire model is 5*20_5A/250VAC, and must meet the explosion-proof requirements. info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
Page 24
(by means of shut off valves) in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process. info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
Page 25
Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked. info@evoheat.com.au 1300 859 933 www.evoheat.com.au...
REGISTER YOUR WARRANTY EvoHeat highly recommend customers complete their warranty details online to ensure efficient warranty claim processing. To register your warranty, scan our QR Code or head to our website and fill in the Warranty Registration Form: https://evoheat.com.au/warranty-registration/...
Need help?
Do you have a question about the Evo Fusion-i and is the answer not in the manual?
Questions and answers