Once the sensor setup is complete, perform a final check of the detection area to ensure that the sensor is installed and
programmed properly.
1.
Perform a manual counting proof using the LZR-SIGMA mobile app, and walk straight through the detection area, both
ways, covering the entire detection area (see pattern below). Be sure to manually count yourself in the app each time
you cross the threshold.
Review the manually counted number against the sensor-counted number and determine if obstructions are affecting
sensor performance or if the sensor mounting orientation is incorrect (see page 6, Sensor Directionality).
2.
Perform another manual counting proof and walk at an angle through the detection zone, entering on the edges of
the detection zone.
Review proof and determine if limits need widened. BEA recommends widening by 6" increments. Review proof and
determine if obstructions are affecting sensor performance or if the sensor mounting orientation is incorrect (see
page 6, Sensor Directionality).
If the results of the manual counting proof are below 90%, contact your integrator to
schedule a video proof via the Sensorio portal for further investigation.
©BEA
| Original Instructions
75.5929.01 LZR-SIGMA 20210630

INSTALLATION VERIFICATION

4
3
1
2
Page 15 of 17