READ BEFORE BEGINNING INSTALLATION/PROGRAMMING/SET-UP

INSTALLATION

The sensor should be
mounted securely to avoid
extreme vibrations.
• All wiring harnesses used must a) be routed separate from any mains or non-class 2 voltage
cables, or b) be rated for the mains voltage and suitable protection.
• Routing means must be used in accordance with national and local codes.
SAFETY
The door control unit and the
header cover profile must be
correctly grounded.

MAINTENANCE

LED STATUS (default settings)
For other LED indications based on relay configuration, see page 5 - J2: Relay Mode.
Page 2 of 8
Page 2 of 8
Choose a location that
does not interfere with
door hardware (e.g. finger
guards, lock rods, etc.).
Only trained and qualified
personnel are recommended
for installation and set-up of
the sensor.
It is recommended to clean
the optical parts at least once
a year or more if required due
to environmental conditions.
MASTER
(red)
Presence detection
(green)
Sensor powered, non-detection
Do not cover the sensor.
Following installation, always
test for proper operation
(according to ANSI 156.10)
before leaving the premises.
SLAVE
(red)
Presence detection
75.5911.03 SUPERSCAN-T 20180719
75.5911.03 SUPERSCAN-T 20180719
Avoid moving objects in the
detection field.
The warranty is invalid if
unauthorized repairs are
made or attempted by
unauthorized personnel.
Do not use aggressive
products to clean
the optical parts.