Now that all of the applicable sensor information has been entered, continue to follow the prompts in the app to guide
you through the sensor setup.
One sensor = NO
Multiple sensors = YES, see Application
Note 78.6034 for more information
©BEA
| Original Instructions
75.5929.01 LZR-SIGMA 20210630
Allow the sensor to learn the field.
At this step, the sensor is learning the
height and will set left and right limits
according to the maximum allowed
width based on mounting height.
MANUAL ADJUSTMENT (preferred): Measure the width of the entryway and increase or decrease
limit accordingly using the + and - buttons. BEA recommends adding 6" to your dimensions to ensure
your area is fully covered.
AUTOMATIC ADJUSTMENT: Follow prompts.
SETUP
You may manually adjust left and
right limits by simply clicking the edit
button beside the given dimension.
Verify that the learned height is
accurate. If not, see Troubleshooting.
Be sure to press CONFIRM
when finished.