1.5.1
Device state
These LEDs provide information about conditions which affect the operation
of the whole device.
The following table applies only to device variants with 2 power supply units:
LED Display
Color
P
Supply
voltage
green
yellow lights up
The following table applies only to device variants with one power supply unit:
LED
Display
P
Supply voltage
The following table applies to every device variant:
LED
Display
Stand-
Stand-by
by
mode
RM
Ring
Manager
RM
ACA
and
memory
Stand-
operations
by
Applies to software releases previous to 06.0.00:
LED
Display
FAULT Signal
contact 1
34
Activity
Meaning
none
Supply voltages 1 and 2 are too low.
lights up
Supply voltage 1 and 2 is on
Supply voltage 1 or 2 is on
Color Activity
none
green lights up
Color Activity
none
green lights up
none
green lights up
flashing
yellow lights up
Flashing
alternately
flashes
synchronously
2 × per period
flashes
synchronously
1 × per period
Color Activity
red
lights up
none
Meaning
Supply voltage is too low
Supply voltage is on
Meaning
Stand-by mode not enabled
Standby mode enabled
The RM function is deactivated.
The RM function is active.
The redundant port is disabled.
The device detects an incorrect configuration of
the HIPER-Ring (for example the ring is not
connected to the ring port).
The RM function is active.
The redundant port is enabled.
Error in the memory operation
Saves a configuration file from the storage
medium ACA to the device.
Saves a configuration file from the device to the
storage medium ACA.
Meaning
The signal contact is open - it is reporting a
detected error.
The signal contact is closed, it is not reporting any
detected errors.
Installation MACH1000