In accordance with IEEE 802.3af and IEEE 802.3at:
Endpoint PSE
Alternative A.
1.6
Display elements
After the supply voltage is set up, the Software starts and initializes the
device. Afterwards, the device performs a self-test. During this process,
various LEDs light up.
1.6.1
Device state
These LEDs provide information about conditions which affect the operation
of the whole device.
ACA
Power
LED
Display
Power Supply voltage
ACA
Storage medium
ACA21
ACA31
RM
Ring Manager
32
RM
Status
Color Activity
—
none
yellow lights up
flashes 4 times
a period
green lights up
—
none
green lights up
flashes 3 times
a period
yellow lights up
—
none
green lights up
flashes 1 time
a period
yellow lights up
Meaning
Supply voltage is too low
Device variants with redundant power
supply:
Supply voltage 1 or 2 is on
Software update is running. Maintain the
power supply.
Device variants with redundant power
supply:
Supply voltage 1 and 2 is on
Device variants with single power supply:
Supply voltage is on
ACA storage medium not connected
ACA storage medium connected
Device writes to/reads from the storage
medium
ACA storage medium inoperative
No redundancy configured
Redundancy exists
Device is reporting an incorrect
configuration of the RM function
No redundancy exists