1.6

Display elements

After the supply voltage is set up, the software starts and initializes itself.
Afterwards, the device performs a self-test. During this process, various
LEDs light up. The process takes around 60 seconds.
OCTOPUS
Figure 1: Display elements
1 - Port status LEDs (here: for ports 1 to 4)
2 - Device status LEDs
1.6.1

Device state

These LEDs provide information about conditions which affect the operation
of the whole device.
LED
Display
P1
Supply voltage 1 Green
P2
Supply voltage 2 Green
FAULT Signal contact
RM
Ring Manager
If the manual adjustment is active on the "FAULT" signal contact, then the
detected error display is independent of the setting of the signal contact.
Installation OCTOPUS 8M/16M/24M/OS32
Release 16 06/2018
2
Color
Activity
Lights up
None
Lights up
None
Red
None
Lights up
None
Green
Lights up
flashing
Yellow
Lights up
1
Meaning
Supply voltage is on
Supply voltage is too low
Supply voltage is on
Supply voltage is too low
The signal contact is closed - it is not
reporting any detected errors.
The signal contact is open - it is reporting
a detected error.
The RM function is deactivated.
The RM function is active.
The redundant port is disabled.
The device detects an incorrect
configuration of the HIPER-Ring (e.g. the
ring is not connected to the ring port).
The RM function is active.
The redundant port is enabled.
19